PCP-005/015/050/150/500/1000
Rev 1.1
2021/02/03
12/45
Copyright © 2021 by TAEHA CORP. All Rights Reserved
4
Pro Pump Operation
4.1
Precautions on Use and Assembly
1.
In connection A(Stator) and B(Rotor)
Use C(Fix Tool) to fix the tools and apply solution(material) inside A(Stator) and on B(Rotor).
Connect A(Stator) and B(Rotor) and rotate them up to the marked position and rotate C(Fix Tool)
in clockwise direction.
Figure 6. Rotor and Stator Connection
Do not activate the Pump without applying the material to the stator. If so, even for a short
duration of time, there might be a damage on the stator.
2.
Eliminating bubbles before liquid discharge
Figure 7.
Eliminating bubbles
When the pump and the controller’s settings are finished, before
applying the solution to the product, rotate the D(Vent Knob) as the
arrow direction one to two rounds to discharge the bubbles and some
liquid(about 5~10 seconds).
When it is confirmed that the bubbles are all eliminated, then close it off
again.
When eliminating bubbles, set the motor speed at low(5~10RPM) to
discharge.