![Tadiran Telecom AVL-200 Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/tadiran-telecom/avl-200/avl-200_service-manual_3238916024.webp)
SKY
-
24
-
POWER SUPPLY
MAIN SWITCH
FROM INDOOR UNIT
14
2
4
6 8
15 16 17
T2
T2
J2
7.3 Wiring the Outdoor Unit
•
Locate the terminal box cover according to the following figures.
•
Remove the outdoor unit side cover.
•
Connect the wires to the terminals, in accordance with the color coding and the
suitable wiring diagrams.
•
Connect the outdoor sensor cable, making sure the connector is properly inserted.
•
Secure the inter-unit electrical cable to the outdoor unit using the clamps.
•
Make sure that all screws and wires are properly fastened. Loose wires or connections
can cause damage and present a fire hazard!
•
Reassemble the side cover.
7.3.1 Outdoor Unit Terminal Box
7.4 Wiring the Indoor Unit
•
Locate the terminal box cover according to the following figures.
•
Remove the indoor unit side cover.
•
Connect the wires to the terminals, in accordance with the color coding and the
suitable wiring diagrams.
•
Make sure that all connections are properly inserted and fastened.
•
Make sure that all screws and wires are properly fastened. Loose wires or connections
can cause damage and present a fire hazard!
•
Reassemble the side cover.