SKY
-
37
-
General Troubleshooting (continued).
Symptom
Probable Cause
Corrective Action
4
In Cool mode: high
pressure, or;
In Heat mode:
outdoor
coil freeze.
1. Run capacitor of outdoor
fan motor is burnt.
2. Winding of outdoor fan
motor is shorted.
1. Replace outdoor fan motor run
capacitor.
2. Replace outdoor fan motor.
5
Only indoor fan
motor and outdoor
fan motor are
working. No
cooling and/or
heating take place.
1. Overload safety device on
compressor is cut out due
to high temperature.
2. Compressor run capacitor
is burnt.
3. Compressor
winding
shorted.
4. Pressure
is
too
high.
1. Switch Off power and try again after
one hour.
2. Replace compressor run capacitor.
3.
Replace
compressor.
4.
Check HP controller. Press RESET
button.
6
No air supply at
indoor unit
(compressor
operates).
1. Indoor fan motor is blocked
or turns slowly.
2. Indoor
fan
motor
capacitor
is burnt.
3. Indoor fan motor winding is
burnt.
4. In Heat mode: delayed
start for indoor fan motor.
5. Clogged
air
filters.
1. Check voltage. Repair wiring if
necessary.
2. Check indoor fan wheel if tight on
motor shaft. Tighten if necessary.
3. Replace indoor fan motor capacitor.
4. Replace indoor fan motor.
5. Normal software delay (max. 20 sec.).
Clean filters.
7
Low Capacity.
1. Lack of refrigerant (will be
accompanied by whistling
noise); causes ice
formation on the
evaporator coil (in Cool
mode).
2. Clogged
air
filters.
1. Unit must be charged (according to
the nameplate) after localizing the gas
leak.
2. Clean
filters.
8
In Heat mode: only
compressor runs,
outdoor and indoor
fan motors are
stopped.
AIR CON indicator
flashes.
A/C operates in De-Icing cycle.
Wait (max.) 10 min. until the A/C resumes
to normal operation.
Содержание ANL-100
Страница 15: ...SKY 15 4 1 Refrigeration Cycle ANL 100...
Страница 16: ...SKY 16 4 2 Refrigeration Cycle AVL 100...
Страница 17: ...SKY 17 4 3 Refrigeration Cycle AVL 120...
Страница 18: ...SKY 18 4 4 Refrigeration Cycle AVL 140...
Страница 47: ...SKY 47 Fig 9 2 Outdoor Unit Case Assembly 1 2 3 4 5 6 7 8 9 14 16 17 18 15 10 11 12 13...
Страница 49: ...SKY 49 Fig 9 3 Outdoor Unit Refrigerant System Components 14 15 16 17 18 1 2 3 4 5 6 7 8 9 10 11 12 13...
Страница 51: ...SKY 51 Fig 9 4 Outdoor Unit Electrical Components 1 2 3 4 5 6 7 8 9 10 11 12 13...
Страница 53: ......
Страница 54: ...EN SKY ANL AVL AVR 100 120 140 V01 R01 JAN 2005...