9.2 Canceling Method
9.2.1 Cancel Status Judgment
The cancel status is judged by the level detection of momentary type cancel switch. Therefore, the
canceling of interlock stop is effective only while the cancel switch is ON.
9.2.2 Cancel Switch Abnormality Judgment
As the cancel switch trouble judgment, if the cancel switch is ON when PTO is ON, a warning code
(W0191) is displayed, and beep is sounded. In the cancel status, the cancel indicator LED of AML
display panel lights up.
The external indicator lamp for cancel shall be red.
1. The warning code and beep sound are maintained for 120 seconds. Even during the warning status, the
warning is stopped when the switch is returned to the neutral.
The sounding of warning beep cannot be muted by the alarm OFF function.
2. If the cancel switch is ON when each of the boom/jib selection setting, outrigger status changeover
setting, and counterweight setting is performed, the warning code and beep sound are maintained for 5
seconds.
Fig. 9.2.1 Cancel indicator LED