background image

Tactical Controls Limited

Ultra-sonic Operator Panel Instruction Manual

Power supply

The control panel requires 0-12 Vac 6VA max. 50Hz supply.

Sensor input

A resistance thermometer PRT100 is supplied as the temperature sensor.

Control outputs

Relay  outputs  are  used  for  both  temperature  and  timer  output.  The  rating  for  both  relays  is
240Vac 5A max.

User interface

The  user  interface  comprises  two  7-segment  green  LED  display,  6  LEDs,  4  green  and  2
amber,  and  five  push  buttons.  The  7-segment  display  is  used  to  indicate  time  setting,  time
remaining,  measured  temperature  and  setpoint  temperature.  The  green  LEDs  are  used  to
indicate  the  status  of  the  display  which  includes  time  setting,  time  remaining,  measured
temperature  and  setpoint  temperature.  The  amber  LEDs  are  for  the  status  of  the  heater  and
timer output.

One of the push buttons "CIRCULAR ARROW" is used to access display time setting, time
remaining,  measured  temperature  and  setpoint  temperature.  Another  button  "UP  ARROW"
enables  the  time  setting  or  setpoint  temperature  to  be  incremented  and  the  third  button
"DOWN ARROW" enables the  time setting or setpoint temperature  to be decremented. The
fourth  button  "HEAT"  is  used  to  enable  the  heater  output  for  temperature  control.  The  last
button  "SONICS"  is  used  to  start  and  stop  the  ultra-sonic  output  timer.  Both  increment  and
decrement buttons are equipped with auto-repeat.

UOP\IM

Page 4

19 April 1996

Issue 1.1

Содержание UOP

Страница 1: ...96 Tactical Controls Limited This document contains proprietary information which is protected by copyright All rights reserved This document or parts thereof may not be reproduced in any form without...

Страница 2: ...quid into which items to be cleaned are immersed The whole is caused to vibrate at 30KHz Microscopic cavitation bubbles within the fluid implode and hammer out adhered dirt from items to be cleaned Th...

Страница 3: ...on six status indicating LEDs and output circuitry for temperature and timer The operator panel is mounted on the fascia plate inside the cleaning unit using six nuts and washers through six studs on...

Страница 4: ...Ds are used to indicate the status of the display which includes time setting time remaining measured temperature and setpoint temperature The amber LEDs are for the status of the heater and timer out...

Страница 5: ...onnectors Blades of 0 11 are used for 12Vac supply and sensor input Blades of 0 25 are used for 240Vac mains heater output and sonic output The 12Vac supply is connected to CONN3 and CONN4 12VAC termi...

Страница 6: ...Tactical Controls Limited Ultra sonic Operator Panel Instruction Manual Fascia label Dimensional drawing UOP IM Page 6 19 April 1996 Issue 1 1...

Страница 7: ...r temperature and timer indications 6 status indicating LED 4 green and 2 amber Keys 5 positive feedback tactile push buttons Connection Faston connectors 2 for mains supply 0 to 12Vac 1 for mains inp...

Страница 8: ...g code UOP You are welcome to order the unit by code or description UOP Ultra sonic cleaning unit Operator control Panel Supplier information Tactical Controls Limited Unit 4 Marlborough Road Lancing...

Отзывы: