* Always remove batteries when not in use

•  The UDC 360 Under Door Camera is powered by four 3Volt Photo Lithium batteries.  Most manufacturers of these 

cells designate them as size 123 or CR123A.  Tactical Electronics systems draw high current; use only GE SANYO, 
ENERGIZER, or DURACELL batteries.  Testing has proven those batteries to provide the longest run time in our 
products.

•  Run times will vary, components in this system are designed to optimize power management and power sharing 

when hard-wired together.  Usage of IR LEDs will also contribute to varied run times.

•  The diagrams below demonstrate proper battery installation and power-up for the UDC 360 Under Door Camera.

 

»

Battery Life Indicator:

The LED power indicator will flash red and green to indicate low 
battery power.  

As battery life continues to diminish the LED indicator will 
illuminate solid red.  After the LED illuminates solid red the 
unit will shut down within 10 minutes.

When battery life is critical the LED indicator will illuminate 
solid blue.  Once this occurs the UDC 360 will only remain 
ON for 10-15 seconds while the system shuts down to protect 
recorded video on the SD card.

 

»

Battery Compartment & Power-Up Procedure:

The UDC 360 (left) requires four 3V Lithium batteries for 
operation.  Use the battery orientation diagram adhered to the 
UDC 360 for reference.

NOTE: For SD card recording, ensure the SD card is inserted 
before powering ON the UDC 360.

The power switch for the UDC 360 is a push button located on 
the side of the unit.  The picture (left) identifies the UDC 360 
power button.  Fully depress the power button to power ON and 
OFF the UDC 360.  

Immediately after the UDC 360 is powered ON the LED indicator 
will illuminate a solid blue for approximately 8-10 seconds while 
the system initializes.  Once the power-up phase is complete 
the LED indicator will illuminate a solid green indicating full 
operational use (If no SD card is inserted, the LED indicator 
will flash red).

NOTE: When the UDC 360 is powered ON all IR LEDS are 
powered OFF by default.

To power OFF the UDC 360, hold down the power button for 3 
seconds to begin power down cycle - when the LED illuminates 
blue release the power button and the unit will power OFF 
within 5 seconds.

NOTE: DO NOT open the battery door before powering OFF the 
UDC 360.  Failure to properly power OFF the unit will result in 
loss of recorded files.

OPERATION AND SUPPORT PUBLICATION

UDC 360 POWER UP

5

Tactical Electronics & Military Supply

LED indicators

Содержание UDC 360

Страница 1: ...ILITY 2200 NORTH HEMLOCK AVE BROKEN ARROW OK 74012 V 866 541 7996 V 918 249 8326 F 918 249 8328 CRUSADER FACILITY 2844 CRUSADER CIRCLE 100 VIRGINIA BEACH VA 23453 V 757 689 0476 F 757 689 3769 UNDER D...

Страница 2: ...2 PROPRIETARY...

Страница 3: ...UNDER DOOR 4 CAMERA SYSTEM UDC 360 3 Manual Contents Kit Identification Power up Operation Monitoring Options Specifications 3 4 5 6 9 10 15 16...

Страница 4: ...rd One Telescoping deployment pole One Hard wire cable with inclusion of Handheld Monitor Pro Used for hard wire operation with Handheld Monitor Pro One Monitoring option of your choice Wrist Monitor...

Страница 5: ...o on the SD card Battery Compartment Power Up Procedure The UDC 360 left requires four 3V Lithium batteries for operation Use the battery orientation diagram adhered to the UDC 360 for reference NOTE...

Страница 6: ...PPORT PUBLICATION UDC 360 OPERATION 6 Tactical Electronics Military Supply IR LED Modes The UDC 360 provides two stages of IR illumination By default IR flood illuminator is powered OFF upon every pow...

Страница 7: ...ion of an RF video signal When a monitor is powered ON the monitor begins receiving the video signal from the UDC 360 Cycle through the channels on the monitor until a picture is displayed Channel Sel...

Страница 8: ...ws The forward camera angle provides a forward view of a room s interior The upward camera angle provides a view of the interior side of a door The left and right camera angles provide left and right...

Страница 9: ...the UDC 360 reinsert the SD card and power ON the unit The UDC 360 will transmit video without the use of SD card recording If the unit is powered ON without an SD card inserted REC ERROR will be dis...

Страница 10: ...t Mounted Monitor WMM The Wrist Mounted Monitor is powered by two 3V Lithium batteries The batteries are to be inserted positive terminal first The power switch for the Wrist Mounted Monitor left is t...

Страница 11: ...via cigarette lighter plug The 3V Lithium batteries that are to be inserted negative terminal first The power switch for the Handheld Monitor left is a rocker type The green LED is illuminated when t...

Страница 12: ...requency simply cycle through each of the four channels until a picture is displayed on screen NOTE Any time the channel is changed on the MMV the shutdown timer is reset Since the initial press of th...

Страница 13: ...ystems When toggling the current channel will be displayed on screen To determine a camera s channel frequency simply cycle through each of the four channels until a picture is displayed on screen Not...

Страница 14: ...the camera system in operation is capable of remote toggling follow the instructions below to toggle between camera views and or IR LED illumination modes Remote toggle camera views Depress the Camera...

Страница 15: ...llumination Depress the IR button on the Handheld Monitor Pro to remotely toggle through IR LED illumination modes HHM Channel Selection If multiple camera systems are in use all monitors are equipped...

Страница 16: ...n POWER SUPPLY Four 3V Lithium batteries CR123A type RUNTIME 1 25 hours HOUSING MATERIAL High density polyethylene HDPE anodized aluminum OPERATING TEMPERATURE RANGE 10 C to 50 C 95 humidity FREQUENCY...

Отзывы: