46 |
www.BabyLock.com
Diagnostics
You may be asked to perform diagnostic tests by Baby Lock's Product Support team or an authorized Baby
Lock retailer.
If necessary press the Plus and Minus keys
simultaneously to take you to the Menu screen.
Press the Plus or Minus key to toggle to the
Diagnostics option. Press the Needle Up/Down
key to open the Diagnostics menu.
Use the Plus or Minus key to toggle through the four
Diagnostics options. Press the Needle Up/Down key
to open the selected Diagnostic test.
N
OTE:
Exit Diagnostics menu screen by
simultaneously pressing Plus and Minus keys.
Encoder:
This test displays the current X Stitch
regulation encoder (left-to-right/right-to-left) and
Y Stitch regulation encoder (front-to-back/back-to-
front) counts.
Pre
ss Needle Up/Down key to open the Encoder Test.
Move the Gallant around the frame.
P
ass: Values for X and Y will increase and decrease
as the machine and carriage are moved.
Press the Needle Up/Down key to return to the
Diagnostics Menu.
Key:
Tests the functionality of the handlebar key
switches. Press any of the four keys on the front or
back handlebars to verify the Gallant is reading the
keys as they are pressed.
Press Needle Up/Down key to open the Key Test.
Press each key on the front or back handlebar
several times.
P
ass: Each time a key is pressed the corresponding
key icon on the diagnostic screen will toggle between
selected/unselected.
Press the Plus and Minus keys simultaneously to
return to the Menu.