– 7 –
Fig. 1
Opened
Closed
Fig. 2
The shaded part is
discharged.
Check ball
Opened
Closed
(6) On the double diaphragm type, in addition to the drive diaphragm, a corrugated PTFE
diaphragm is provided at the liquid end. The space between these two diaphragms is
filled with buffer solution (glycerin, purified water or silicone oil), in order to transmit the
reciprocal motions of the drive diaphragm accurately and uniformly to the PTFE
diaphragm (front diaphragm). As a result, the diaphragm’s working life is dramatically
extended.
6 Model Code
(1) Drive box type
X: Vertical type Y:Horizontal type
(2) Pump head
DA:Direct-drive diaphragm WA:Double diaphragm
MA:Hydraulic diaphragm MWA:Hydraulic double-diaphragm
PA:Plunger
(3) Number of pump heads
1:Single 2:Duplex
(4) Model type
(5) Relief valve
R:with Relief valve Blank:without Relief valve
Fig. 3 Double Diaphragm Type: SXWA, SYWA
Buffer solution (glycerin, purified water, silicone oil, etc.)
Drive diaphragm
Front diaphragm
a
b
c
(1) (2) (3)
(4)
S
(11)
(9) (10)
(7)
(6)
(5)
(8)
SXDA data̲p01-p21
Adobe PageMaker 6.0J/PPC