Safety Warning
Attention
Improper contact with electrical appliances can result in electric shock, serious injury
or death. To avoid and prevent personal injury or death from electric shock, please
follow the instructions carefully.
●
●
●
●
●
●
●
●
●
●
Overview
:
This instrument is a handheld line test tool. Appliline line types are increased,
functions are more, and the scope of application is wider. It is an essential test tool
for telecom engineering personnel, wiring engineering personnel, and network
maintenance personnel.
Main Function:
●
●
●
●
●
Function and Operation
:
1.
The function of wire tracking refers to finding the required line quickly among
numerous ones. This instrument is suitable for searching RJ45 interface network line
and RJ11 interface telephone line.
Operating method:
a)
b)
c)
d)
e)
Attention
It is available to wear headphone while in a noisy place.
2.
The wire sequence calibration is for the physical connection of the open, short,
wrong, and reverse connection of the network line.
Operation method:
a)
b)
c)
Attention
The eight LED Wire Sequence Lights on the transmitter and receiver correspond to
the eight lines in the network cable.
3.
Use the transmitter is enough for detection.
Operation method:
Battery positive and negative judgment:
a)
b)
c)
Level determination:
a)
b)
c)
4.
Only use transmitter to detect.
The operation method to determine TIP or RING line:
a)
b)
c)
Determine the idle, ringing, and off-hook status of the telephone line during
work:
a)
b)
c)
5.
Only transmitter can be used to detect the connection status of the line:
a)
b)
c)
6.
Transmitter undervoltage indication: Rotate the function knob of the transmitter to
the “SCAN” position. When the transmitter's battery is lower than the working
voltage, the hunt function indicator “SCAN” on the transmitter will flash. When the
indicator is flashing, please Replace the battery in time.
Receiver battery voltage indication: Turn on the power of the transmitter, press and
hold the receiver “SCAN” button to bring the probe to the RJ45 connector of the
transmitter, and adjust the volume adjustment knob of the receiver to the maximum
volume position. If no sound is heard from the receiver or When you have a small
sound, please replace the battery in time.
Note: The receiver will automatically shut down if there is no operation within 15
minutes.
General technical indicators
Temperature range:
Operating temperature: 0 ~ 40OC, maximum relative humidity of 80% (non-con-
densing).
Storage temperature: -10 ~ 50 OC, maximum relative humidity of 80% (non-con-
densing, no battery)
Altitude: <2000m (m)
Explosion-proof type: IP 40
Signal transmission distance: about 300m
Battery: transmitter 6F22/9V, 1; receiver 6F22/9V, 1
Maintaining
Do not attempt to repair this instrument unless you are professional and own
relevant calibration, performance testing, and repair information.
Clean the case regularly with a damp cloth and a small amount of detergent. Do not
use abrasives or chemical solvents.
Battery replacement
Please follow the steps below to replace the battery:
1. Use a screwdriver to remove the screw from the battery cover.
2. Remove the battery cover and remove the old battery.
3. Replace the new battery of the same specification.
4. Install the battery cover and tighten the back cover with screws.
- 07 -