background image

1

Owner’s Manual

HDMI/Mini HDMI  

Cable Tester 

Model: T040-001-HDMI

PROTECT YOUR INVESTMENT!

Register your product for quicker service and ultimate peace of mind. 

You could also win an ISOBAR6ULTRA surge protector—a $100 value!

www.tripplite.com/warranty

1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support

Copyright © 2018 Tripp Lite. All rights reserved. 

Este manual esta disponible en español en la página de Tripp Lite:  

www.tripplite.com/support

Ce manuel est disponible en français sur le site Web de Tripp Lite :  

www.tripplite.com/support

Русскоязычная версия настоящего руководства  

представлена на веб-сайте компании Tripp Lite по адресу:  

www.tripplite.com/support

18-04-380-933794-EN.indd   1

5/7/2018   4:47:25 PM

Содержание T040-001-HDMI

Страница 1: ...00 value www tripplite com warranty 1111 W 35th Street Chicago IL 60609 USA www tripplite com support Copyright 2018 Tripp Lite All rights reserved Este manual esta disponible en espa ol en la p gina...

Страница 2: ...dentifier Compatible with HDMI versions 1 0 through 2 1 Fast and accurate verification of HDMI cables with Type A A A C or C C connectors Displays 19 pin to pin wire map and shield connection status t...

Страница 3: ...e one at a time When testing uninstalled patch cable you can leave the Main Tester and Remote Identifier connected When testing installed cable you will need to remove the Remote Identifier from the M...

Страница 4: ...with diagrams showing which pins should illuminate for each connection type Note When no connection is detected between the connectors of the cable being tested the LEDs will not illuminate Straight...

Страница 5: ...ate to show in what order they are wired For example in the diagram below when the Master unit shows pin 14 illuminated pin 19 on the Remote unit will illuminate indicating those connections are cross...

Страница 6: ...onnections Open Circuit If the same LEDs on both the Master and Remote units remain off the corresponding wire is an open circuit Master Remote Power Off Continuity Sweep 04 380 933794 EN indd 6 5 7 2...

Страница 7: ...Short Circuit If a short circuit is detected the Remote unit s LEDs will not illuminate but the Master units LEDs will illuminate brighter Master Remote Power Off Continuity Sweep 04 380 933794 EN in...

Страница 8: ...ules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause...

Отзывы: