background image

4

Detecting Connections

Note: 

This product is designed to test cable lengths up to 164 ft. (50 m).

When a cable connection from both ends is detected, the LEDs will 

illuminate. Listed below are detected connection examples with diagrams 
showing which pins should illuminate for each connection type. 

Note: 

When no connection is detected between the connectors of the cable being 

tested, the LEDs will not illuminate

Straight (Proper) Connection 

When all LEDs illuminate on both the Master and Remote units, the cable is 
properly wired and ready to install/use.

Master

Remote

Power

Off

Continuity

Sweep

18-04-380-933794-EN.indd   4

5/7/2018   4:47:25 PM

Содержание T040-001-HDMI

Страница 1: ...00 value www tripplite com warranty 1111 W 35th Street Chicago IL 60609 USA www tripplite com support Copyright 2018 Tripp Lite All rights reserved Este manual esta disponible en espa ol en la p gina...

Страница 2: ...dentifier Compatible with HDMI versions 1 0 through 2 1 Fast and accurate verification of HDMI cables with Type A A A C or C C connectors Displays 19 pin to pin wire map and shield connection status t...

Страница 3: ...e one at a time When testing uninstalled patch cable you can leave the Main Tester and Remote Identifier connected When testing installed cable you will need to remove the Remote Identifier from the M...

Страница 4: ...with diagrams showing which pins should illuminate for each connection type Note When no connection is detected between the connectors of the cable being tested the LEDs will not illuminate Straight...

Страница 5: ...ate to show in what order they are wired For example in the diagram below when the Master unit shows pin 14 illuminated pin 19 on the Remote unit will illuminate indicating those connections are cross...

Страница 6: ...onnections Open Circuit If the same LEDs on both the Master and Remote units remain off the corresponding wire is an open circuit Master Remote Power Off Continuity Sweep 04 380 933794 EN indd 6 5 7 2...

Страница 7: ...Short Circuit If a short circuit is detected the Remote unit s LEDs will not illuminate but the Master units LEDs will illuminate brighter Master Remote Power Off Continuity Sweep 04 380 933794 EN in...

Страница 8: ...ules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause...

Отзывы: