Page 38
Troubleshooting
Fault Cause
Remedy
Touch screen only functions
partly.
Connection cable from touch
screen to PC defective (the
part that is connected to the
PC).
Replace connection cable.
MEMORY TEST FAIL at start-
up.
Memory defective.
Replace PC.
No function.
The mains plug has not been
connected.
The mains switch has not
been switched on.
Mains fuse triggered.
Connect to the mains socket.
Switch on the mains switch.
Replace fuse.
No picture.
Power supply not connected.
Video cable not connected.
Display defective.
Check display's power supply
and plug connections.
Connect video cable.
Replace display.
No sound
Software volume control not
turned up.
Audio cable not connected.
Loudspeaker defective.
Turn up the software volume
control.
Connect audio cable.
Replace loudspeaker.
One or several keys
doesn’t/don’t work.
Flat connector not connected.
Key not correctly assembled
or defective.
Check plug connections.
Check key or replace.
Coins are not correctly
counted.
Wrong value programmed.
Check program settings.
Inserted coins fall through.
No power to the coin checker.
Coin checker dirty.
Coin channel not assigned.
Coin checker defective.
Check power supply.
Clean coin checker.
Change programming.
Replace coin checker.
Poor coin acceptance.
Coin checker dirty.
Clean coin checker.
Counter does not work.
Counter defective.
Replace counter.