background image

1

Stepper motor controller

The stepper motor controller SMS14 is used for the control of unipolar and bipolar motors.
Through adjustment of the jumpers (J1-J4), the following settings can be made.

Jumpers J1-J4 on the PCB

The positions of the jumpers are only read once as the device boots (= when supplying it with power).

If the jumpers are adjusted during operation, their positions will only be updated if the device is re

-

started.

Technische Alternative RT GmbH

SMS14U

SMS14B

A-3872 Amaliendorf, Langestraße 124

Tel +43 (0)2862 53635     [email protected]

Vers. 2.01

J1

not set

Control of a unipolar step motor in half step mode (8 states)

set

Control of a bipolar step motor with single-phase full step (4 states)

J2

not set

500 steps

set

1000 steps

J3

not set

30% holding current, when target position is reached

set

no holding current

J4

not set

Reference drive sets Closed state, 0% means Closed

set

Reference drive sets Open state, 0% means Open

 

J1 J2

J4

J3

Отзывы: