ROW weighing scales operation manual
REV: C1, June 2015
ROW weighing scales operation manual
Press the
UNIT
key and
M+
key together in the weighing mode, it
will display “
F0 H-L
”, press
ZERO
key to enter, use
TARE
key to select
“
SET HI
” or “
SET LO
”, press
ZERO
key to enter, use
G/N
key to move
active digit, use
TARE
key to change value, use
UNIT
key to clear value.
After you enter the value, press
ZERO
key to sure, press
UNIT
key to
escape.
4.3 Set check weighing mode
Press the
UNIT
key and
M+
key together in the weighing mode to
enter setting mode, press
TARE
until display show “
F3 OFF
”, press
ZERO
key to enter, press
TARE
key until display show “
BEEP
”, press
ZERO
key to enter, press
TARE
key to select
BP 2
(check mode 2),
BP3
(check mode 3),
BP1
(no beep), press
ZERO
key to sure, press
UNIT
key to escape.
4.4 NOTE
The weight must be greater than 20 scale divisions for the
check-weighing to operate.
To disable the Check-Weighing function enter zero into both limits
by pressing the
UNIT
key and
M+
key together in the weighing mode,
then the current limits are shown. then set zero and store the zero
values.
5 Accumulated Total
5.1 Note
The scale can be set to accumulate manually by pressing the
M+
key. See the PARAMETERS Section for details of selecting the method
using function "
F4 P RT
". The accumulation function is only available
when weighing.
Please note before every accumulate operate, scale need return to
-4-
zero, and only press
M+
key when stable, when weight less than 20d,
accumulate operate will be invalid.
5.2 Accumulate operate
The weight displayed will be stored in memory when the
M+
key is
pressed and the weight is stable.
The display will show "
ACC 1
" and then the total in memory for 2
seconds before returning to normal. (after do accumulate operate, M+
indicator will turn on) If the optional RS-232 interface is installed the
weight will be output to a printer or PC.
Remove the weight, allowing the scale to return to zero and put a
second weight on. Press the M+ key, the display will show "
ACC 2
"
and then the new total.
Continue until all weights have been added.
*Note: after you change weighing unit, accumulate value will be clear.
5.3 memory recall
To view the totals in memory press
M+
key in zero point (ZERO
indicator on).
5.4 memory clear
To clear the memory, just press
UNIT
key
5.5 automatically accumulate
At first, you need set scale to auto accumulate mode, Press the
UNIT
key and
M+
key together in the weighing mode, it will display “
F0
H-L
”, press
TARE
key until display show “
f4 prt
”, press
ZERO
key to
enter, press
TARE
key to select “
p auto
”, press
ZERO
key to sure, then
you need set baud rate and M+ format, print type.
After you set, AUTO indicator on.
-5-
Содержание ROW Series
Страница 1: ...ROW Weighing Scales...