Total no. of pages: 30
PAGE 27
Anleitung EAG80_26_00_2017_03_28_GB
Version 28.04.2017
8
Commissioning EAG80
Steps 1 to 4 are normally already set.
8.1
Theoretical adjustment of scales
Settings under 4.4.1 AuFLo
Press and hold 0/ESC and Start/Stop simultaneously until ALLGE appears in the display.
WAAGE
AuFLo
Selection of display steps
StAbE
Basic settings weighing elements (Number / Max Load / mV/V)
StAbA
Number of connected weighing elements
LASt
Maximum load of connected weighing elements (see type plate of
weighing element)
StAbS
mV/V value of connected weighing elements (see type plate of
weighing element)
StAbE
Adjustment completed
8.2
Input of time and date
Settings under 4.1.2 Time
ALLGE
Uhr
Input of time
dAt
Input of date
JAhr
Input of year
8.3
Settings for printers or large-size displays
Settings under 4.2 Menu Interfaces (
Schnt
CON 1
Function of 1st serial interface
AuS
Interface 1 deactivated
GAZ
Output format for T.E.L.L. large-size display
druck
Output format for T.E.L.L. printer, data logger or Telog software
GAJun
Output format for T.E.L.L. large-size display (only for Jun 1, 2, 3, 4)
CON 2
Function of 2nd serial interface (optional)
AuS
Interface 2 deactivated
GAZ
Output format for T.E.L.L. large-size display
druck
Output format for T.E.L.L. printer, data logger or Telog software
GAJun
Output format for T.E.L.L. large-size display (only for Jun 1, 2, 3, 4)
bAud
Entry of baud rate of serial interfaces (1 and 2)
PArIt
Entry of parity of serial interfaces (1 and 2)
bIt L
Entry of bit length of serial interfaces (1 and 2)