![T-Drill 40231 Скачать руководство пользователя страница 82](http://html1.mh-extra.com/html/t-drill/40231/40231_instruction-manual_811680082.webp)
INSTRUCTION MANUAL
82
Problem
Cause
Remedy
Tap “Cycle start” on
control panel:
ALARM: Collaring
process cannot be
started
Air pressure off
Check air pressure line, switch
on air pressure to the collaring
unit: press Reset on control
panel
Is the collaring tool fastened
properly?
Lifting cylinder not up (20-B1.1)
Check the cylinder positions and
move to correct position using
MANUAL
Locking cylinder not on the side
(20-B2.0)
Work piece sensor is activated (10-
B4)
Check work piece sensor, there
should be nothing pushing
sensor.
The S1 and S2 axis are not in home
/ start position (+/- 2 deg)
Do homing.
If the problem is not solved with the help of trouble shooting instructions, contact your
local T-DRILL dealer.
Give your contact information
• The name of the company
• Your own name and position
• Telephone number
• Fax number
• e-mail –address
To accelerate the problem solution, please give the following information:
• The serial number of the machine
• Type code
• The reading of the piece counter
• Short description of the appeared problem.
Содержание 40231
Страница 1: ...INSTRUCTION MANUAL COLLARING MACHINE S 80...
Страница 14: ...INSTRUCTION MANUAL 14 3279 2613 2569 2238 1015 3321...