9. TROUBLESHOOTING
Problem
Cause
Remedy
The screen of the
control panel is
blank
Power supply not connected
Connect current / Check that
main switch of the S-80 is in ON
position.
Machine doesn’t
move
The emergency switch knob has not
been released
The safety light curtain has not
been reset
After having pushed the
emergency switch, the machine
will not start again unless
releasing the STOP-switch and
pushing the safety curtain reset
button.
Work cycle doesn’t
start
Light curtain has been interrupted. Reset the light curtain
Machine stops in
the middle of the
work cycle
Emergency stop or the safety light
curtain was interrupted in the
middle of the work cycle.
Reset Emergency Stop and
curtain and Do Homing.
A controlled machine reset
is done by pushing the Reset
button continuously for 10
seconds.
Tap “Homing” on
screen:
ALARM: Homing
sequence cannot be
started
Air pressure off
Check air pressure line, switch
on air pressure to the collaring
unit: press Reset on control
panel
Lifting cylinder not down (20-B1.0)
Locking cylinder not in the middle
(20-B2.1)
or
Lifting cylinder not up (20-B1.1)
Locking cylinder not on the side
(20-B2.0)
Check the cylinder positions and
move to correct position using
MANUAL
Are collaring settings OK?
Check settings.
Are tool settings OK?
Check settings.