Installation Cont’d… 

2.  Remove the screw, shown as 'A' in fig. 3, 

fixing the plastic cap and remove it. 

3.  Pass the wires through the hole in the base, 

shown as 'C' in fig. 3 and using the two 
screws included in the package, ('B' in fig. 3) 
fix the thermostat base on the junction box 
or directly on the wall. 

4.  In order to easy the electrical wiring, remove 

the 3-poles wiring block ('D' in fig. 3), 
applying a little pressure towards the 
external on the lever 'E' in fig. 3, which 
actually fixes it to the base. 

 
 

 

 

 

5.  As shown in the diagram on the right 

connect the boiler to the terminals 1 and 2, 
(the relay performs a changeover according 
to a the temperature raising/falling). 

6.  Re-insert the terminal block in the original 

place, pressing it slightly towards the base 
until the plastic tooth snaps. 

7.  Insert from the left the plastic cap in order to 

perfectly couple it to the base, then screw 
the screw formerly removed. 

 

 

 

 

8.  Insert 2 1,5V AA batteries in the thermostat 

body, paying attention to the polarity (see 
fig. 5). 

 

 

 

 

 

9.  Couple the thermostat, inclined by 45° on 

the right side as in fig. 6, so that the plastic 
teeth, shown with the arrows, fits in the 
relevant slots in the base. 

 

 

 

 

 

 

10. Press the thermostat body towards the 

plastic base, paying attention to couple the 
pins on the thermostat with the terminal 
block on the base. When the thermostat 
body reaches the plastic tooth 'A' in fig. 7, 
slight press it with a movement to the 
internal side, still pressing the thermostat 
body towards the base, until the tooth snaps 
in the relevant hole. 

 