41CL User Manual
© 2019, Systemyde International Corporation
42
ALPHA register
4
3
2
1
module identifier
M4 M3 M2 M1
page address
-
P5 P4 P3
The Image Database information is returned in both the ALPHA register and the display,
in the format shown below. Since a module image may be up to 32K in length (8 pages),
more than one physical address can return with a match, but only the information in the
actual database entry is returned. If no address match is found the function will result in a
NO MATCH
error message. Only the first match (the search proceeds from lowest
database address upwards) will ever be returned.
ALPHA register
10
9
8
7
6
5
4
3
2
1
physical address
M4 M3 M2 M1
-
T
-
P5 P4 P3
Searches with a valid module identifier always return the corresponding contents of the
Image Database, even if the entry is unprogrammed.
The type digit
T
specifies the type of image, according to the table below.
T
digit
image type for this module identifier
0
4K image (one page)
1
8K image (two pages)
2
16K image (all four banks in one page)
3
16K (four pages)
4
32K (all four banks in two pages)
This function automatically executes the search in the 50X Turbo mode, but even so the
search may take several seconds when searching for an address match. A
SEARCHING
message is written to the display while a search is in progress.