uLory User Guide
16
<STX3>
enter the value of Hex except
0x for STX
-
Set
the
length
in
AT+STXL=<Length> before
entering the desired length;
For example, in order to
register number 1,2 and 3,
users firstly input AT+STXL=3
and then AT+STX=31,32,33
AT+ETXL=<Length>
0(0~3) unit : byte
0 = not used.
Set the length of ETX(End of
text) of serial data
AT+ETX=<ETX1>
AT+ETX=<ETX1>,<ETX2>
AT+ETX=<ETX1>,<ETX2>,
<ETX3>
00(00~7F)
-
Set ETX(End of
text) of Serial data
-
Refer to the ASCII table and
enter the value of Hex except
0x for ETX
-
Set
the
length
in
AT+ETXL=<Length> before
entering the desired length;
For example, in order to
register number 1,2 and 3,
users firstly input AT+ ETXL
=3 and then AT+ ETXL
=31,32,33 .
AT+DMS=<Length>
0(0~116)
unit: byte
Serial data will be transmitted to
LoRa after a specific length of
data as specified is received
The priority is given in order of Length, STX or ETX and Time in case of that uLory includes
features of Time, STX, ETX, and Length in the condition for Serial data reception.
For example, if 1237890 will firstly be recognized according to the condition of Length if
1237890456 is entered with less than the 1-second-interval and the condition is set as