Check if the computer and the sLAN/all are using the same subnet mask (For example, if the sLAN/all is using 

255.255.255.0 as its subnet mask, your computer must use the same subnet mask). Also, check if the default 

gateway is set properly. 

 

If an incorrect IP address is assigned from the DHCP server, please contact your network administrator to 

check if the DHCP server is assigning a correct IP address for your sLAN/all device. 

 

Software Utility Problem 

 

When problem occurs while using the COM Redirector, a virtual COM port emulator, check if the correct virtual 

port number is used when running the application. Go to the COM port configuration window and check if all 

values are set correctly

 

 

 

Содержание sLAN/all

Страница 1: ...User Manual www sysbas com sLAN all Version 1 1 1 2018 06 11...

Страница 2: ...1 Revision History Revision Date Document Version Pages Description March 6 2017 1 0 All New June 11 2018 1 1 24 25 RS 422 Multi Drop Mode Added...

Страница 3: ...res 6 Applied Field 8 3 Hardware Specifications 10 Case and Connectors 10 LEDs 10 Serial Port Pin Specifications 11 Reset Tact Switch 11 4 Connecting Network 12 First time Use 12 Before connecting 12...

Страница 4: ...sWiFi all User Manual 3 6 Configuration Utility 23 Search 23 Configuration 23 7 Appendix 24 Troubleshooting 24 Product Specifications 26...

Страница 5: ...mation regarding controlling and managing sLAN all with its connected devices Documents Related to sLAN all Technical documents related to sLAN all are as follows All documents in our website is up to...

Страница 6: ...ch sysbas com to receive fast responses Any questions requests suggestions or comments are welcomed 2 For instant response call us Our technical team will always provide detailed consultation and guid...

Страница 7: ...ector to providing maximum serial communication speed of 921 6kbps and RJ45 connector for Ethernet side with maximum 100Mbps speed connection A sLAN can be connected remotely to control monitor any ty...

Страница 8: ...des following 1 Unit of sLAN all Device 1 Unit of 5V DC Adaptor or a Micro USB B Cable 1 LAN Cable 1 sLAN all Quick Manual Paper Manual Class A equipment Sellers or users should be aware of the fact t...

Страница 9: ...ough the network sLAN Serial Tunneling This allows the serial cable between a computer and a serial device to be extended through the network This makes the cable length limitless where there is a net...

Страница 10: ...man Machine Interface Logistic Storage Conveyor Belt Medical Equipment Controllers on Inspection Equipment Alarm Device Biometric Sensors Home Appliances Electronics Power Management Device Game Conso...

Страница 11: ...released LED Shows the status of sLAN all LAN Port This 8 pin RJ45 port is used for connecting sLAN all to devices such as Ethernet card hub router and other network devices Power Connector The device...

Страница 12: ...GND DSR RTS CTS 1 2 3 4 5 6 7 8 9 DCD RI TXD TRxD GND RXD 1 2 3 4 5 6 7 8 9 RS 422 485 TXD TRxD RXD Pin No RS 232 RS 422 RS 485 1 DCD TXD TRXD 2 RXD TXD TRXD 3 TXD RXD 4 DTR 5 GND GND GND 6 DSR 7 RTS...

Страница 13: ...e of the sLAN all you can either connect to the device with a web browser or use configuration utility If you know the static IP address type it in a web browser to connect to the configuration web pa...

Страница 14: ...sWiFi all User Manual 13...

Страница 15: ...work speed must be 100Mbps or faster If a sLAN all is directly connected to the computer it will also work If setting the below environment is difficult use the SGConfig utility to configure the devic...

Страница 16: ...gure network environment The Submit button must be clicked to save the changes you have made For changes to take effect the device must be rebooted You can do it from Reboot menu If changes are not sa...

Страница 17: ...ion Type is set to Static IP If it is set to DHCP current IP address will be displayed and changes can t be made Subnet Mask 255 255 255 0 Configure current subnet mask address Set the IP address manu...

Страница 18: ...operational protocol for the serial port COM Redirector This allows sLAN all serial port to be used as a virtual COM port for Windows When using this mode serial settings follow what is set in the vi...

Страница 19: ...ple if the value is set to 0 when the serial device sends 100 bytes of ASCII through a sLAN all to a socket in a server the data will be sent to the server immediately Although this allows for real ti...

Страница 20: ...Default Description transmission and reception When this is set to enabled TCP data is set immediately Delays between communication is be minimized but this is not suitable for high speed data or pack...

Страница 21: ...shown on the screen is ignored but those set from the COM redirector in your computer will take place The main features are as follows Menu Default Description Interface RS 232 Current communication p...

Страница 22: ...ication Options No Odd Even Flow Control None Current hardware flow control set for the serial communication If the RTS CTS is chosen RTS signal will be automatically controlled based on the flow of s...

Страница 23: ...need an ID and a password They can be configured as shown in the below screen This setting will take immediate effect without rebooting the device Reboot The device will be restarted If there are any...

Страница 24: ...ch Run SGConfig and click Search button to look for any sLAN alls in the same network Configuration Select the device you would like to configure from the searched list Click the Configure button A sL...

Страница 25: ...ration Problems When using TCP IP network check if your computer and sLAN all are connected to the same network Use ping command to check the connection between the computer and the sLAN all The IP ad...

Страница 26: ...ly If an incorrect IP address is assigned from the DHCP server please contact your network administrator to check if the DHCP server is assigning a correct IP address for your sLAN all device Software...

Страница 27: ...DC Type External Diameter 3 5 mm Internal Diameter 1 35 mm Power Connector USB Type Micro B USB Cable Dimension W L H 40 9 74 0 16 5mm 1 61 x 2 91 x 0 65in Weight 34 7g 1 22oz Operating Temperature 40...

Страница 28: ...2020 SystemBase CO Ltd All rights reserved This manual is a document protected by Copyright law Unauthorized copying duplicating publishing of some or all of contents without prior consent from System...

Страница 29: ...eserved Email Purchase Quotation overseas sysbas com Technical Support RMA tech sysbas com www sysbas com Tel 82 2 855 0501 Fax 82 2 855 0580 If you have any inconvenience while using the product plea...

Отзывы: