INSTALLATION

All Systembase C500 series codecs are designed to
fit a standard 19” rack. Each unit measures 
44.45mm high (1U).  Notes for installing:-

1/ Do not obstruct any air vents that the product may
have.

2/ Do not mount the unit directly above or below 
other equipment within the rack. It is recommended 
to leave a space of 1U between units.

3/ Where possible connect the M4 earth bonding 
point to the rack enclosure frame. 

CONNECTIONS

1/ Audio connections are located at the rear of the 
unit and presented on electronically balanced XLR 
connectors. The headroom can be configured 
b12dBu and +18dBu.

2/ AES3 is supported on balanced, transformer 
isolated, XLR connectors.

3/ ISDN: The C510ip-s supports ISDN on the slot 
labelled “ISDN 1/2”.

4/ The C510ip-s supports AoIP streaming on the slot
labelled “ISDN3/4 IP”. This Ethernet interface is 
electrically isolated from the Ethernet interface used 
by the manager port. Both ports are hosted by 
different processors maximising security between 
the often public AoIP function and the management 
function.

5/ The X.21 port is supported on a female 15 D-type
connector and is presented as a DTE. To connect to
a DCE you will require a straight cable.

6/ The Aux data port supports inband AUX data 
transmission at speeds from 2400bps to 9600bps.
Also supported here is a optically isolated trigger 
that will force the dialling of the ISDN. In addition 
there is a set of alarm relay contacts the can be 
programmed to reflect the alarm state if the codec.

7/ The Manger port is used for connecting to a host 
computer network for the purposes of codec 
management. The WEB GUI is based on XML data 
and  lightweight JS. This means that it will function 
on Chrome, Mozilla, IE8+ MAC OS and mobile 
phones without requiring installable code.

If required a network management tool called 
“EasyMon” can be downloaded from the 

Systembase website which enables monitoring of 
multiple codecs in a single web browser window.

8/ The final two 9way DSUB connectors are used for
serial management at 9600bps. These connectors 
also support two sets of end to end relay contact 
closures that can be used instead of the AUX data 
function.

CONTROLS AND INDICATORS

VFD Display 

A 24 character by 2 line VFD (Vacuum Fluorescent 
Display), provides comprehensive information on 
the configuration of the unit and current status.

VU Meters

20 bit True RMS Digital VU Meters for monitoring 
Left and Right audio channels with Peak Hold. The 
VU Meter range is -60dB to 0dB with red LEDS to 
indicate clip.

Menu Buttons

  

Menu Scroll Up / Previous button.

  

Menu Scroll Down / Next button.

  

Menu Select / Edit button is used to select the

configuration which is to be modified.

  

Menu Backspace button. 

NO

NO / Cancel button is used to answer No or 

to abort the configuration change. The NO button is 
also used to exit a menu level and return to the level
above. Pressing the NO button several times will 
always take the user back to the Title display.

YES

YES / Confirm button is used to answer 

YES or to confirm the configuration change.

DIAL Button 

The 

DIAL

 button is used to dial the ISDN call(s).

Keypad Dial

The first depression of the 

DIAL

 button will take the 

unit into the Keypad Dial menu as the first option. 
This allows the user to type in an ISDN number via 
the keypad.

Page 4

Содержание C510ip-s

Страница 1: ...Page 1 SystemBas IP Audio Codecs USER MANUAL C510ip s REL300 upwards...

Страница 2: ...P Ethernet Mode 14 IP Packet Size 14 SIP Remote Port 15 SIP Local Port 15 SIP Audio Port 15 SIP Public IP 15 X21 Audio 15 Backup Options 15 Backup Monitor 15 Backup Threshold 15 Restore Time 15 Reserv...

Страница 3: ...Kbps SIP Compatibility with other Manufacturers SIP Server Registration and telephony support SIP Hybrid Function supporting standard G711 and HD voice calls Unicast Simulcast Multicast IGMPV2 X 21 Co...

Страница 4: ...to a host computer network for the purposes of codec management The WEB GUI is based on XML data and lightweight JS This means that it will function on Chrome Mozilla IE8 MAC OS and mobile phones with...

Страница 5: ...er to access 1 of 26 pre stored configuration memories MENU Patch Dial 1 PATCH 1 The and buttons can be used to select the required patch 1 of 26 A third depression of the DIAL button instructs the un...

Страница 6: ...Page 6 FRONT REAR PANELS...

Страница 7: ...Page 7 MENU MAP UP DOWN RIGHT EDIT BACKSPACE YES CONFIRM EDIT NO CANCEL EDIT LEFT UP DOWN RIGHT EDIT BACKSPACE YES CONFIRM EDIT NO CANCEL EDIT LEFT...

Страница 8: ...Page 8 IP MENU MAP UP DOWN RIGHT EDIT BACKSPACE YES CONFIRM EDIT NO CANCEL EDIT LEFT...

Страница 9: ...for the ISDN B Channels INFO CH1 CALLER ID 01256880123 Clearing Cause The Clearing Cause for each of the available ISDN B Channels is displayed INFO CH1 CLEARING CAUSE IP Link Status MENU IP Link Stat...

Страница 10: ...d with ISDN operation of the unit ISDN Audio Options MENU ISDN Audio Options ISDN Audio Format MENU ISDN Audio Format APTX 15K2 Mono 128Kbps The and buttons can be used to select the required ISDN Aud...

Страница 11: ...SDN parameters associated with each ISDN B Channel can be changed The C510ip s has 2 ISDN B Channels The following 3 option menus are repeated for all available Channels ISDN Remote Address MENU CH1 R...

Страница 12: ...once it has been confirmed On completion press the YES button to save the changes and the NO button to abort the changes If a Mutlicast address is specified and AutoCon initiated then the codec will...

Страница 13: ...is disrupted for any reason including power reset IP Local Options MENU IP LOCAL OPTIONS The next level of the menu system allows the user to modify the Local IP parameters IP Local Name MENU IP LOCAL...

Страница 14: ...be manually adjusted 1 n Packets as required IP Group ID MENU IP GROUP ID 1234 The IP Group ID is associated with the Systembase AoIP protocol and used to prevent the C510ip s Codec from accepting IP...

Страница 15: ...22K5 Mono 192Kbps APTX 12K2 Stereo 192Kbps APTX 15K2 Mono 128Kbps APTX 7K5 Stereo 128Kbps APTX 7K5 Mono 64Kbps APTX 3K7 Stereo 64Kbps NOTE When operating in Mono only the Left Input and Left Output a...

Страница 16: ...g the Backup Options menu NOTE When operating in ISDN Backup Master Slave mode it is advised that the DCE should carry X 21 termination resistors Backup Master X21 IP Slave X21 IP The X 21 port is the...

Страница 17: ...droom MENU Headroom 12dBu Headroom can be configured to either level System Options The user can modify the global System configurations of the Codec Country Options There are a number of ISDN paramet...

Страница 18: ...0BASE TX half duplex Note The C510ip s supports DNS which will automatically configure the DHCP is enabled If you wish to manually configure the DNS server address then that may be achieved via the WE...

Страница 19: ...e been configured and registered on the SIP server it is possible to place a call from one to the other using the other codecs user name For example if the two codec names were codecA and codecB then...

Страница 20: ...your router On your computer web browser type in the IP address of the codec http 192 168 1 2 A Windows Login screen will be displayed The default Username is admin and the default password is admin...

Страница 21: ...tiple codecs in a single browser window with minimal overhead EasyMON is free and maybe downloaded from the systembase website www systembase com Included in the download are instructions that will gu...

Страница 22: ...S3 set loopback Off On set x21 APTX 3K7 Stereo 64Kbps APTX 7K5 Mono 64Kbps APTX 7K5 Stereo 128Kbps APTX 15K2 Mono 128Kbps APTX 12K2 Stereo 192Kbps APTX 22K5 Mono 192Kbps APTX 15K2 Stereo 256Kbps APTX...

Страница 23: ...This facility allows the user to connect AES3 signal sources that are asynchronous to the codecs network interface The electrical characteristics of these connections is detailed below I P Connectors...

Страница 24: ...OM 7 Relay 1 N O 8 GND 9 Opto 1 i p Opto Input Trigger by strapping to ground Manager Output Port Type V 24 RS232 Fixed DTE Speed 9600bps 8 n 1 Signals TXD RXD SIG GND Connector 9 way Dsub Female PIN...

Страница 25: ...to 90 RH Operating Altitude 3000 meters WARRANTY INFORMATION Systembase Limited warrants that this product is free from defects in materials or workmanship for 12 months from delivery Upon proof of p...

Страница 26: ...able at the time of publication The manufacturer reserves the right to change details without notice Systembase is a trademark of Systembase Limited apt X is a trademark of APT Licensing Ltd All trade...