| 3
200515 | A004
Introduction
Smoke gas fan ZRS from Systemair is used to
prevent insufficient draft from stoves, ovens
and fire places. The smoke gas fan can be
installed without interfering with the chimney
pipe.
Note!
ZRS is not waterproof. This should especially be
considered when using metal ducts.
Transport and storage
All Systemair fans are packaged at the factory to
withstand normal transport handling.
When handling the goods use suitable lifting
equipment in order to avoid damage to fans or
personnel.
The fans do not have any lifting eye bolts.
Note!
-
Do not lift the fan by the connecting cable,
connection box, impeller or inlet cone.
-
Avoid blows or shock loads.
-
Be on the alert for any damage on the
packaging or the fan.
-
The fans should be stored in a dry area
protected from the weather and dirt until
final installation.
-
Avoid excessive storage periods (we
recommend one year maximum).
Safety information
Systemair fans are not ready-to-use products
and are only to be put into operation after they
have been built into machines, duct systems or
if safe operation has been ensured by a contact
protection grid.
Installation must be carried out in such a way
that direct contact with moving parts is not
possible.
Installation has to be performed by authorized
personnel only!
The fans must not be used in an explosive
atmosphere. Connect to a flue duct, max.
temperature 200 °C.
The fans must be installed so that safe
operation and maintenance is ensured. Safety
devices (e.g. motor protection, contact
protection grid etc), must not be dismantled,
circumvented or made inoperative. Roof fans
are exclusively intended for extract air
applications.
Note!
-
Before servicing or maintenance, switch off
power (all-pole circuit breaker), and make
sure the impeller has come to a standstill.
-
The fans can have sharp edges and corners
which may cause injuries.
-
The smoke gas fan must always be running
when the fireplace is being used.
Installation
Installation, electrical connection and
commissioning are only to be performed by
authorized personnel and in accordance with
the requirements of the installation.
Electrical connection according to the wiring
diagram in the terminal box, markings on
terminal blocks or on cable.
Use a dummy plug seal for the compression
gland fitting as well.
The fan must be installed so that vibrations are
not transmitted to duct systems or frame of
building.
Make sure the assembly of the fan is firmly fixed
and stable.
The fans must be assembled so that service and
maintenance can be performed easily and
safely.