Technical Data

• Safety elements may not be dismantled, circumvented or deactivated.

• Wear protective equipment during all work in the vicinity of the unit.

• Do not allow children to play with the device.

2.1

Intended Use

• Abide by the system-related conditions and requirements of the system manufacturer or plant constructor.

• Keep all the warning signs on the device and in a legible condition.

• The device is not to be used by persons (including children) with reduced physical, sensory or mental capabilities, or

lack of experience and knowledge, unless they have been given supervision or instruction.

• The system should operate continuously, and only be stopped for maintenance/service.

• Do not connect tumble dryers to the ventilation system.

• Make sure that filters are mounted before starting the unit.

2.2

Admonitions

Danger

• Make sure that the mains supply to the unit is disconnected before performing any maintenance or

electrical work!

• All electrical connections and maintenance work must be carried out by an authorized installer and in

accordance with local rules and regulations.

Warning

• This product is not intended to be used by children or people with reduced physical or mental ability or

lack of experience and knowledge, if no instruction concerning the use has been given by the person
responsible for their safety or that this person is supervising the operation. Children should be supervised
so that they can not play with the product.

• Beware of sharp edges during mounting and maintenance. Use protective gloves.

Warning

• Risk of injury due to rotating parts that have not come to a complete standstill after mains supply to the

unit have been disconnected.

3

Technical Data

3.1

Power consumption and fuse size

Re-heater

1670 W

Fans

176 W

Total power consumption

1846 W

Fuse

10 A

229391 | v02

Содержание SAVE VTR 300/B

Страница 1: ...Document in original language 229391 v02 SAVE VTR 300 B Installation instructions GB...

Страница 2: ...s the rights to alter their products without notice This also applies to products already ordered as long as it does not affect the previously agreed specifications Systemair is not liable or bound by...

Страница 3: ...it 5 3 4 2 Condensation outside of the unit 6 4 Delivery Transport Storage 6 4 1 Transport and storage 6 4 2 Delivery Unloading 6 5 Prerequisites for Installation 6 5 1 Location and Space Requirements...

Страница 4: ......

Страница 5: ...ve make a note of the specification and production number from the type label which can be found next to the external connections and inside of the unit Fig 1 Type label Position Description 1 Product...

Страница 6: ...Admonitions Danger Make sure that the mains supply to the unit is disconnected before performing any maintenance or electrical work All electrical connections and maintenance work must be carried out...

Страница 7: ...Technical Data 3 3 2 Dimensions and Weight Fig 2 Dimensions of left hand unit 229391 v02...

Страница 8: ...4 Technical Data Fig 3 Dimensions of right hand unit Water coil connections Drainage Height with mounting bracket The unit weight is 56 kg 229391 v02...

Страница 9: ...unit is in tended to be stopped by the user manually or due to calendar function we recommend to install air tight dampers at ex tract and supply air ducts The dampers will ensure that no air circulat...

Страница 10: ...d be stored and transported in such a way that it is protected against physical damage It should be covered so dust rain and snow cannot enter and damage the unit and its components Important Use the...

Страница 11: ...es delivery Note The drainage connection is plugged in the bottom of the unit at delivery To use the drainage remove the rubber seal and connect the drainage pipe Connect the drainage pipe to the sewe...

Страница 12: ...8 Installation C concrete bricks W wood block G gypsum M mineral wool X adaptable height according to needs Make sure the mounting bracket is completely level 229391 v02...

Страница 13: ...o avoid sound propagation Use acoustic insulation and sound attenuators Note The type of ventilation ducts and insulation differ for each building and climate zone If the ventilation drawing is not pr...

Страница 14: ...s It is possible to go back to previous menus and make modifications Finally choose heating type or none Finish startup wizard with OK button All additional changes post startup wizard must be recorde...

Страница 15: ...l appliances Part 2 40 Particular requirements for electrical heat pumps air conditioners and dehumidifiers EN 50106 Safety of household and similar appliances Particular rules for routine tests refer...

Страница 16: ...SAVE VTR 300 B Installation instructions 229391 en_GB 2021 02 05 v02 Systemair UAB Lin st 101 LT 20174 Ukmerg LITHUANIA Phone 370 340 60165 Fax 370 340 60166 www systemair com...

Отзывы: