fantech

DO NOT CONNECT POWER SUPPLY until fan is completely installed. 
Make sure electrical service to the fan is in the locked “OFF” position.

1.  Fantech recommends installation of this product by a trained, licensed, certified mitigation professional.  Incorrect installation will void any and all 

product warranties or liability. Verification of safe/acceptable radon levels after installation is required. 

   Check your local code restrictions for additional safety measures that may be needed for proper code compliant installation.

2. This fan has rotating parts and safety precaution should be exercised during installation, operation and maintenance.

3. WARNING! TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS - OBSERVE THE FOLLOWING:
   a.  Use this unit in the manner intended by the manufacturer. If you have any questions, contact your manufacturer’s representative or contact us 

directly.

  
   b.  CAUTION: Before installation, servicing or cleaning unit, switch power off at service panel and lock the service disconnection means to prevent 

power from being switched on accidentally. When the service disconnection means cannot be locked, securely fasten a prominent warning 
device, such as tag, to the panel.

  
   c. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire- 

  rated construction.

  
   d. The combustion airflow needed for safe operation of fuel burning equipment may be affected by this unit’s operation.  Follow the heating  

  equipment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection Association (NFPA), the  
  American Society of Heating, Refrigeration, and Air Conditioning Engineers (ASHRAE) and the local code authorities.

  
   e. When cutting or drilling into wall and ceiling, do not damage electrical wiring and other hidden utilities.

  f.  Ducted fans must always be vented to the outdoors.

4. WARNING! Check voltage at the fan to see if it corresponds to the motor name plate.

5. For radon mitigation use only. DO NOT use to exhaust hazardous or explosive materials and vapors.

6. Do not use this fan with any solid state speed control device.

GUARDS MUST BE INSTALLED WHEN FAN IS WITHIN REACH OF PERSONNEL OR WITHIN SEVEN (7) FEET OF WORKING LEVEL OR WHEN DEEMED ADVISABLE 
FOR SAFETY.

Note

Warning / Important note

Avertissement / Note 

importante

Information

Technical information

Information technique

Practical tip

Conseil pratique

The ducting from this fan to the outside of the building has a strong effect on the air flow, noise and energy use of the fan.  Use the 
shortest, straightest duct routing possible for best performance, and avoid installing the fan with smaller ducts than recommended.  
Insulation around the ducts can reduce energy loss and inhibit mold growth.  Fans installed with existing ducts may not achieve their rated 
air flow.

Содержание fantech Rn2EC

Страница 1: ...OX Rn2EC Inline Radon Fan Rn 1 pc Operation and Installation Manual 1 pc PIÈCES DANS LA BOÎTE Rn2EC Ventilateur pour radon en ligne Rn 1 pc Manuel d installation 1 pc registration fantech app REGISTER THIS PRODUCT TO INCREASE YOUR PRODUCT WARRANTY BY AN EXTRA YEAR in USA only PARTS IN THE BOX Rn4EC Inline Radon Fan Rn 1 pc LDVI Couplings 2 pcs Operation and Installation Manual 1 pc PIÈCES DANS LA ...

Страница 2: ...ndards including fire rated construction d The combustion airflow needed for safe operation of fuel burning equipment may be affected by this unit s operation Follow the heating equipment manufacturer s guidelines and safety standards such as those published by the National Fire Protection Association NFPA the American Society of Heating Refrigeration and Air Conditioning Engineers ASHRAE and the ...

Страница 3: ...r use with 3 schedule 40 PVC pipe Rn2EC 4 Rn4EC 4 are designed for use with 4 schedule 40 PVC pipe Prior to installation the suction pipe should be terminated at the exterior wall The suction pipe should be installed with slight incline to drain water from the fan DO NOT connect fan directly to building structure WIRING DIAGRAM 120 V Supply Motor White Red Control Yellow Blue Green Green Black or ...

Страница 4: ...ation for any breach of warranty WARRANTY VALIDATION The user must keep a copy of the bill of sale to verify purchase date These warranties give you specific legal rights and are subject to an applicable consumer protection legislation You may have additional rights which vary from state to state This warranty does not apply to any Fantech product or part which has failed as a result of faulty ins...

Страница 5: ...nnement de cet appareil pourrait modifier la circulation d air de combustion nécessaire au fonctionnement sécuritaire des appareils de combustion Suivez les consignes du fabricant pour les appareils de chauffage et respectez les normes de sécurité comme celles établies par la National Fire Protection Association NFPA la American Society for Heating Refrigeration and Air Conditioning Engineers ASHR...

Страница 6: ...u d aspiration sur un mur extérieur Le tuyau d aspiration devrait être installé avec une pente légère pour drainer l eau du ventilateur NE PAS attacher le ventilateur directement dans la structure du bâtiment 120 V Approvisionnement Moteur Blanc Rouge Contrôle Jaune Bleu Vert Vert Noir ou brun Noir Bleu Pouvoir Blanc Potentiomètre 0 5 10 Pour réduire la vitesse du ventilateur utilisez un petit tou...

Страница 7: ... d usine en matière de qualité d exécution ou de matériau Il sera peut être nécessaire de retourner le produit à l usine Fantech accompa gné d une copie du contrat de vente et du numéro d autorisation de retour POUR RETOURNER UN PRODUIT À L USINE VOUS DEVEZ Obtenir un numéro d autorisation de retour pour ce faire communi quer avec Fantech aux États Unis au numéro 1 800 747 1762 ou au Canada au num...

Страница 8: ...make technical changes For updated documentation please refer to www fantech net Fantech Fantech se réserve le droit de faire des changements tech niques Pour de la documentation à jour s il vous plaît se référer au www fantech net ...