SystemAir Fantech FQ 80 Скачать руководство пользователя страница 6

6

fantech

Installation

Step 1.

Remove the grille by gently squeezing the wire springs and extracting 
them from the slots in the housing.

Step 2.

Remove the wire box cover and install the 3 brackets on the fan housing. 
(Figure. 3-1, Figure. 3-2).

Power supply 
protective tube

Housing

Fan outlet

Ceiling joist

Hanger bar

Wire box cover

Wire box

Ceiling

Figure 2

Figure 3

Joist

A

Spacing A on center joist

Insert Suspension bracket

16 inches

Figure 3-1

24 inches

Figure 3-2

Figure 3-1

Figure 3-2

Figure 4

The unit should only be installed in a ceiling. The size of joists should be at 
least 2” wide and 4” high . The space between two joists should be 16”. 
From the above surface of the suspended ceiling there should be minimum 
9” distance to the roof. (Figure 2) Select the suspension brackets as 
shown in (Figure 3)

1.  When installing, keep the number of elbows and bends to a minimum. If necessary, long radius elbows or bends are  recommended.
2.  Duct sealant, caulk, or tape should be applied to all seams, including around the opening in the wall or ceiling on the interior and around exterior 
     building penetrations, to prevent air leakage and maximize air performance.
3.  Flex, spiral, or snap lock ducting may be used. If using rigid duct, Fantech FC clamps are recommended to connect duct work to the fan (see 
     illustration 2). FC clamps make an air tight seal at the connection points and reduce vibrations transmitted throughout the duct system.
4.  To minimize static pressure losses and promote adequate airflow, minimize duct run lengths where possible. If using flex duct, keep duct runs 
     straight and taut.
5.  If installing in an unconditioned space, covering the fan with insulation is recommended to prevent condensation from forming.
6.  For general ventilation applications, at least 8 ft of insulated flexible duct shall be installed between the exhaust or supply grille(s) and the fan.
7. A 4 inch rigid duct recommended for best performance.

The ducting from this fan to the outside of the building has a 
strong effect on the air flow, noise and energy use of the fan.  
Use the shortest, straightest duct routing possible for best 
performance, and avoid installing the fan with smaller ducts than 
recommended.  Insulation around the ducts can reduce energy loss 
and inhibit mold growth. Fans installed with existing ducts may not 
achieve their rated air flow.

Содержание Fantech FQ 80

Страница 1: ...y grilles s and the fan For kitchen range hood remote ventilation applications where metal duct is generally required by code a metal sound attenuator shall be installed between the range hood and the...

Страница 2: ...Do not use in the cooking area Figure 1 11 Do not block the air intakes or exhaust 12 Power supply wiring is to be No 14 AWG wire or larger suitable for at least 90 C 190 F 13 Not for use outdoors 14...

Страница 3: ...entilateur doit tre ad quatement mis la terre 10 Ne pas utiliser dans une aire de pr paration de repas Figure 1 11 Ne pas bloquer les entr es ou les vacuations d air 12 Le c blage d alimentation lectr...

Страница 4: ...utilizar en el rea usada para cocinar figura 1 11 No bloquee las entradas ni la salida de aire 12 Las conexiones de alimentaci n deben realizarse con cables calibre 14 AWG o m s gruesos aptos para al...

Страница 5: ...60 Hz 25 26W 4W 80 FQ110FL 120V 60 Hz 30 26W 4W 110 Sp cification du ventilateur Mod le Consommation d nergie W D bit d air pi3 min Puissance Moteur clairage lampe fluorocompacte Veilleuse FQ 80 120V...

Страница 6: ...exterior building penetrations to prevent air leakage and maximize air performance 3 Flex spiral or snap lock ducting may be used If using rigid duct Fantech FC clamps are recommended to connect duct...

Страница 7: ...s possible Figure 6 Step 6 To complete the installation install the lamps if applicable and mount the grille Figure 5 Figure 6 Wiring diagram For Fan Light Combination For Fan Only Units Maintenance 1...

Страница 8: ...l air 3 Conduits flexibles en spiral ou en verrou d accrochage peuvent tre utilis s Si vous utilisez un conduit rigide les pinces de raccordement FC de Fantech sont recommand es pour relier les condu...

Страница 9: ...nstallation poser les lampes s il y a lieu et fixer la grille Figure 5 Figure 6 Sch ma de c blage Pour la combinaison ventilateur clairage Pour les unit s ventilateur seulement Entretien 1 Couper le c...

Страница 10: ...dimiento de aire 3 Flex espiral o complemento de ducto tipo snap lock se pueden utilizar Si utiliza conducto r gido se recomienda Fantech FC abrazaderas para conectar los conductos al ventilador vea l...

Страница 11: ...ura 6 tape 6 Para finalizar la instalaci n instale las l mparas si corresponde y monte la rejilla Figura 5 Figura 6 Diagrama de conexiones Para la combinaci n de extractor con luces Para extractores n...

Страница 12: ...allation for any breach of warranty WARRANTY VALIDATION The user must keep a copy of the bill of sale to verify purchase date These warranties give you specific legal rights and are subject to an appl...

Страница 13: ...un d faut d usine en mati re de qualit d ex cution ou de mat riau Il sera peut tre n cessaire de retourner le produit l usine Fantech accompagn d une copie du contrat de vente et du num ro d autorisat...

Страница 14: ...talaci n o reinstalaci n por incumplimiento de la garant a VALIDACI N DE LA GARANT A El usuario debe conservar una copia de la constancia de compraventa para verificar la fecha de compra Estas garant...

Страница 15: ...15 fantech Notes Notas...

Страница 16: ...Fantech Fantech se r serve le droit de faire des changements techniques Pour de la documentation jour s il vous pla t se r f rer au www fantech net Fantech se reserva el derecho de hacer modificacion...

Отзывы: