background image

Do not touch the heat exchanger fins. 

These fins are sharp and could result in cutting injuries.

Do not place items which might be damaged by moisture 

under the indoor unit. 

Condensation may form if the humidity is above 80%, the 

drain outlet is blocked or the filter is polluted. 

After a long use, check the unit stand and fitting for 

damage.

 

If damaged, the unit may fall and result in injury.

To avoid oxygen deficiency, ventilate the room 

sufficiently if equipment with burner is used together 

with the air conditioner.

Arrange the drain hose to ensure smooth drainage.

Incomplete drainage may cause wetting of the building, 

furniture etc.

Never touch the internal parts of the controller.

 

Do not remove the front panel. Some parts inside are 

dangerous to touch, and a machine trouble may happen.

Do not operate the air conditioner with a wet hand. 

An electric shock may happen. 

Never expose little children, plants or animals directly to 

the air flow. 

Adverse influence to little children, animals and plants may 

result.

Do not allow a child to mount on the outdoor unit or 

avoid placing any object on it.

 

Falling or tumbling may result in injury.

Do not operate the air conditioner when using a room 

fumigation - type insecticide. 

Failure to observe could cause the chemicals to become 

deposited in the unit, which could endanger the health of 

those who are hypersensitive to chemicals.

Do not place appliances which produce open fire in 

places exposed to the air flow from the unit or under the 

indoor unit.

 

It may cause incomplete combuston or deformation of the unit 

due to the heat.

Do not install the air conditioner at any place where 

flammable gas may leak out. 

If the gas leaks out and stays around the air conditioner, a fire 

may break out. 

This appliance can be used by children age from 8 years 

and above and persons with reduced physical,sensory or 

mental capabilities or lack of experience and knowledge 

if they have been given supervision or instruction 

concerning use of the appliance in a safe way and 

understand the hazards involved,children should not play 

with This appliance.Cleaning and user maintenance 

should not  be made by children without supervision.

When capacity of indoor unit greater than the sum of 

100%, capacity of indoor unit will be attenuated.

When capacity of indoor unit greater than or equal to the 

sum of 120%, in order to ensure the effectiveness of 

machine, and then try to open the indoor units at 

different time.

The outdoor unit window-shades should be periodic 

cleaning in case of being jammed.

This window-shapes is heat dissipation outlet of components, 

if being jammed will cause the components shorten their 

service life spans because of overheated for a long time. 

2

The temperature of refrigerant circuit will be high, please 

keep the interconnection cable away from the copper tube.

Poor environmental conditions,  the appliance should be 

maintained a month and a half or so; If the environment con-

dition is good, may be extended appropriately maintenance 

cycle. 

2.    OPERATION RANGE

Use the system in the following temperature and 

pressure for safe and effective operation. The Max 

operation temperature for the air conditioner. 

(Cooling/Heating)

NOTE

1. If air conditioner is used outside the above conditions, it may         

cause the unit to function abnormally.

2. The phenomenon is normal that the surface of air conditioning 

may condense water when the relative larger humidity in room, 

please close the door and window.

3. Optimum performance will be achieved within these operating 

temperature range. 

4.The A-weighted sound pressure level is below 70 dB.

5.The temperture sound below 55

 during transporting.

6. The sound pressure level is below 70 dB(A)

Table 2-1

 

Cooling operation

Heating operating

Mode

Temperature

   Outdoor
temperature

     Room
temperature

   -20

℃~

27

  

17

℃~

32

15

℃~

27

-5

℃~

55

Parameter

Mode

PS

   High

     Low

4.2MP

3.4MP

This appliance can be used by children aged from 8 years and 

above and person with reduced physical, sensory or mental 

capabilities or lack of experience and knowledge if they have

been given supervision or instruction concering use of the 

appliance in a safe way and understand the hazards involved.

Children shall not play with the appliance.

Cleaning and user maintenance shall not be made by children 

without supervision.

Содержание 319124

Страница 1: ...Outdoor unit Mini VRF Heat Pump OWNER S MANUAL GB SYSVRF2 AIR EVO A HP R...

Страница 2: ...m the air conditioner you purchased depend on model The actual shape shall prevail NOTE This air conditioner comprises an indoor unit outdoor unit and a connection pipe Outdoor unit Air outlet 1 2 3 4...

Страница 3: ...ce with national wiring regulations Do not use the air conditioner for other purposes In order to avoid any quality deterioration do not use the unit for cooling precision instruments food plants anim...

Страница 4: ...volved children should not play with This appliance Cleaning and user maintenance should not be made by children without supervision When capacity of indoor unit greater than the sum of 100 capacity o...

Страница 5: ...stop in order to prevent sending heat wind 3 7 Defrost in the heating operation During heating operation outdoor unit sometimes will frost To increase efficiency the unit will start defrosting automat...

Страница 6: ...le Recoverable Recoverable Recoverable Recoverable Recoverable P8 F1 E1 High pressure protection M HOME for the indoor and outdoor units does not match Display Function Instruction 25 26 27 28 29 30 3...

Страница 7: ...h sound is heard when the system is in cooling operation or at a stop When the drain pump optional accessories is in operation this noise is heard A pishi pishi squeaking sound is heard when the syste...

Страница 8: ...tdoor unit and indoor unit heat exchanger is dirty The air filter is dirty Inlet outlet of indoor outdoor units is blocked Doors and windows are open Sunlight directly shine Too much heat resource Out...

Страница 9: ...s off after a lapse of certain time Check whether the timer operation is started when the TIMER ON is indicated on the display Up to the set time the air conditioner will automatically start and the a...

Страница 10: ...uent on and off of unit or operating time is too long in places where the air conditioning is on for 24 hours a day As the use of the unit for many years will eventually lead to a dust layer the perfo...

Страница 11: ...Certified www systemair com 16126000A19882 V E...

Отзывы: