For example, in early summer or winter.

▪  Check and remove all objects that may clog the air inlets and outlets 

of the indoor and outdoor units. 

▪  Clean the air filter and external shell of the unit. Please contact the 

installation or maintenance personnel. The installation/operation 
manual of the indoor unit includes maintenance tips and cleaning 
procedures. Make sure that the clean air filter is installed in its 
original position. 

▪  Turn on the main power supply 12 hours before this unit is operated 

in order to ensure that the unit runs smoothly. The user interface is 
displayed once the power is turned on.

For example, at the end of winter and summer.

▪  Run the indoor unit in the fan mode for about half a day to dry the 

internal parts of the unit.

▪  Turn off the power supply.  
▪  Clean the air filter and external shell of the unit. Please contact the 

installation or maintenance personnel to clean the air filter and 
external shell of the indoor unit. The installation/operation manual of 
the specialized indoor unit includes maintenance tips and cleaning 
procedures. Make sure that the clean air filter is installed in its 
original position.

This product contains fluorinated greenhouse gases as stipulated in 

the Kyoto Protocol. Do not discharge the gas into the atmosphere.
Based on the applicable law, the refrigerant must be checked regularly 

for leakages. Please contact the installation personnel for more 

information.

The refrigerant in the air conditioner is relatively safer, and usually 
does not leak. If the refrigerant leaks, and comes in contact with 
burning objects in the room, it will produce harmful gases.
Shut down any flammable heating device, ventilate the room and 
contact the agent of the unit immediately.
Do not use the air conditioner again until the maintenance 
personnel has confirmed that the refrigerant leakage has been 
sufficiently resolved.

▪  This product contains the warranty card that was completed by the 

agent during installation. The customer must check the completed 

warranty card and keep it properly. 

▪  If you need to repair the air conditioner during the warranty period, 

please contact the agent and provide the warranty card.

Warning

7.1 Maintenance after Unit has been Shut Down 

for a Long Period

7.2 Maintenance Before Unit is Shut Down for

 a Long Period

7.3 About the Refrigerant

7.4 After-sales Service and Warranty

7.4.1 Warranty period

In the following situations, the "maintenance cycle" and "replacement 
cycle" may be shortened.
The unit is used in the following situations:

▪  Temperature  and  humidity  fluctuations  are  outside  the  normal 

ranges. 

▪  Large  power  fluctuations  (voltage,  frequency,  waveform  distortion 

etc.) (must not use the unit if the power fluctuations exceed the 
allowed range). 

▪  Frequent collisions and vibrations. 
▪  The air may contain dust, salt, harmful gas or oil such as sulphite 

and hydrogen sulphide. 

▪  Frequent on and off of unit or operating time is too long (in places 

where the air conditioning is on for 24 hours a day).

As the use of the unit for many years will eventually lead to a dust 
layer, the performance of the unit will degenerate to a certain extent. 
As professional skills are needed to dismantle and clean the unit, and 
for the optimal maintenance effects of this unit, please contact your 
agent for more details.
When you request the agent for assistance, please remember to state:

▪  Complete model name of the air conditioner. 
▪  Date of installation. 
▪  Details on the fault symptoms or errors, and any defects.

▪  Do not attempt to modify, dismantle, remove, reinstall or repair 

this unit, as the improper dismantling or installation may result 
in electric shock or fire. Please contact the agent. 

▪  If the refrigerant accidentally leaks, make sure that there is no 

fire around the unit. The refrigerant itself is completely safe, 
non-toxic and non-flammable, but it will produce toxic gases 
when it accidentally leaks and comes in contact with flammable 
substances generated by existing heaters, and burning devices 
in the room. You must get a qualified maintenance personnel to 
verify that the point of leakage has been repaired or rectified 
before you restore the operations of the unit.

Warning

7.4.2 Recommended maintenance and inspection

7.4.3 Shorter maintenance and replacement cycle

8

The partial units shall only be connected to an appliance suitable 
for the same refrigerant.
This unit is a partial unit air conditioner, complying with partial unit 
requirements of this International Standard, and must only be 
connected to other units that have been confirmed as complying 
to corresponding partial unit requirements of this International 
Standard.

Warning

For equipment that contains fluorinated greenhouse gases in 
quantities of 5 tonnes of CO2 equivalent or more,but of less than 50 
tonnes of CO2 equipment,at least every 12 months, or  where a 
leakage detection system is installed, at least every 24 months.
For equipment that contains fluorinated greenhouse gases in 
quantities of 50 tonnes of CO2 equivalent or more,but of less than 
500 tonnes of CO2 equipment,at least every six months, or  where 
a leakage detection system is installed, at least every 12 months. 
For equipment that contains fluorinated greenhouse gases in 
quantities of 500 tonnes of CO2 equivalent or more,at least every 
three months ,or  where a leakage detection system is installed, 
at least every six months. 
Non-hermetically sealed equipment charged with fluorinated 
greenhouse gases shall only be sold to the end user where evidence
is provide that the installation is to be carried out by an undertaking 
certified person.
Only certificated person is allowed to do installation, operation and 
maintenance.

    

This product has the fluorinated gas, it is forbidden to release to air. 
Refrigerant type: R410A/8Kg
Volume of GWP: 2088;  tonnes CO2 equivalent    
GWP=Global Warming Potential

Attention:
Frequency of Refrigerant Leak Checks

7.3.1 

Important information for the refrigerant

▪ 

▪ 

▪ 

▪ 

▪ 

Содержание 319124

Страница 1: ...Outdoor unit Mini VRF Heat Pump OWNER S MANUAL GB SYSVRF2 AIR EVO A HP R...

Страница 2: ...m the air conditioner you purchased depend on model The actual shape shall prevail NOTE This air conditioner comprises an indoor unit outdoor unit and a connection pipe Outdoor unit Air outlet 1 2 3 4...

Страница 3: ...ce with national wiring regulations Do not use the air conditioner for other purposes In order to avoid any quality deterioration do not use the unit for cooling precision instruments food plants anim...

Страница 4: ...volved children should not play with This appliance Cleaning and user maintenance should not be made by children without supervision When capacity of indoor unit greater than the sum of 100 capacity o...

Страница 5: ...stop in order to prevent sending heat wind 3 7 Defrost in the heating operation During heating operation outdoor unit sometimes will frost To increase efficiency the unit will start defrosting automat...

Страница 6: ...le Recoverable Recoverable Recoverable Recoverable Recoverable P8 F1 E1 High pressure protection M HOME for the indoor and outdoor units does not match Display Function Instruction 25 26 27 28 29 30 3...

Страница 7: ...h sound is heard when the system is in cooling operation or at a stop When the drain pump optional accessories is in operation this noise is heard A pishi pishi squeaking sound is heard when the syste...

Страница 8: ...tdoor unit and indoor unit heat exchanger is dirty The air filter is dirty Inlet outlet of indoor outdoor units is blocked Doors and windows are open Sunlight directly shine Too much heat resource Out...

Страница 9: ...s off after a lapse of certain time Check whether the timer operation is started when the TIMER ON is indicated on the display Up to the set time the air conditioner will automatically start and the a...

Страница 10: ...uent on and off of unit or operating time is too long in places where the air conditioning is on for 24 hours a day As the use of the unit for many years will eventually lead to a dust layer the perfo...

Страница 11: ...Certified www systemair com 16126000A19882 V E...

Отзывы: