System Sensor SpectrAlert Advance Series Скачать руководство пользователя страница 4

D690-03-00 

I56-2769-015R 

 

 

©2010 System Sensor

The  horn  and/or  strobe  will  not  work  without  power.

  The  horn/strobe  gets  its 

power from the fire/security panel monitoring the alarm system. If power is cut off 

for any reason, the horn/strobe will not provide the desired audio or visual warning.

The horn may not be heard.

 The loudness of the horn meets (or exceeds) current 

Underwriters  Laboratories’  standards.  However,  the  horn  may  not  alert  a  sound 

sleeper  or  one  who  has  recently  used  drugs  or  has  been  drinking  alcoholic  bever-

ages. The horn may not be heard if it is placed on a different floor from the person 

in hazard or if placed too far away to be heard over the ambient noise such as traffic, 

air conditioners, machinery or music appliances that may prevent alert persons from 

hearing the alarm. The horn may not be heard by persons who are hearing impaired.

NOTE:

 Strobes must be powered continuously for horn operation.

The signal strobe may not be seen.

 The electronic visual warning signal uses an extremely 

reliable xenon flash tube. It flashes at least once every second. The strobe must not be in-

stalled in direct sunlight or areas of high light intensity (over 60 foot candles) where the visual 

flash might be disregarded or not seen. The strobe may not be seen by the visually impaired.

The signal strobe may cause seizures.

 Individuals who have positive photoic response 

to visual stimuli with seizures, such as persons with epilepsy, should avoid prolonged 

exposure to environments in which strobe signals, including this strobe, are activated.

The signal strobe cannot operate from coded power supplies.

 Coded power supplies 

produce interrupted power. The strobe must have an uninterrupted source of power in order 

to operate correctly. System Sensor recommends that the horn and signal strobe always 

be used in combination so that the risks from any of the above limitations are minimized.

WARNING

The Limitations of Horn/Strobes

Three-Year Limited Warranty

System  Sensor  warrants  its  enclosed  product  to  be  free  from  defects  in  ma-

terials and workmanship under normal use and service for a period of three 

years from date of manufacture. System Sensor makes no other express war-

ranty  for  this  product.  No  agent,  representative,  dealer,  or  employee  of  the 

Company has the authority to increase or alter the obligations or limitations 

of this Warranty. The Company’s obligation of this Warranty shall be limited 

to the replacement of any part of the product which is found to be defective 

in materials or workmanship under normal use and service during the three 

year period commencing with the date of manufacture. After phoning System 

Sensor’s toll free number 800-SENSOR2 (736-7672) for a Return Authorization 

number,  send  defective  units  postage  prepaid  to:  System  Sensor,  Returns 

Department, RA #__________, 3825 Ohio Avenue, St. Charles, IL 60174. Please 

include  a  note  describing  the  malfunction  and  suspected  cause  of  failure. 

The  Company  shall  not  be  obligated  to  replace  units  which  are  found  to  be 

defective because of damage, unreasonable use, modifications, or alterations 

occurring  after  the  date  of  manufacture.  In  no  case  shall  the  Company  be 

liable  for  any  consequential  or  incidental  damages  for  breach  of  this  or  any 

other Warranty, expressed or implied whatsoever, even if the loss or damage 

is caused by the Company’s negligence or fault. Some states do not allow the 

exclusion or limitation of incidental or consequential damages, so the above 

limitation or exclusion may not apply to you. This Warranty gives you specific 

legal rights, and you may also have other rights which vary from state to state.

FCC Statement

SpectrAlert Strobes and Horn/Strobes have been tested and found to comply with the 

limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits 

are designed to provide reasonable protection against harmful interference when the 

equipment is operated in a commercial environment. This equipment generates, uses, 

and can radiate radio frequency energy and, if not installed and used in accordance 

with the instruction manual, may cause harmful interference to radio communications. 

Operation of this equipment in a residential area is likely to cause harmful interference 

in which case the user will be required to correct the interference at his own expense.

Please refer to insert for the Limitations of Fire Alarm Systems

Figure 4. WaLL mounT produCT:

A0348-00

Figure 5. CeiLing mounT produCT:

A0369-00

Figure 6. WaLL mounT produCT WiTH baCk box SkirT:

A0349-00

4-wire mounting plate

2-wire mounting plate

Figure 7: CeiLing mounT produCT WiTH baCk box SkirT:

A0370-00

Figure 8. WaLL mounT Horn/STrobe WiTH WeaTHerprooF baCkbox:

Figure 9. WaLL and CeiLing mounT WeaTHerprooF baCkboxeS:

NOTE: Wall and Ceiling models may be used interchangeably (wall products may be used on the ceiling and ceiling products may be used on the wall).

NOTE: Use all four mounting plate screws when installing outdoor units. 

A0418-00

A0417-00

Содержание SpectrAlert Advance Series

Страница 1: ...pplications indoors and outdoors They are designed to be used in 12 or 24 volt DC or FWR full wave rectified systems These products are electrically backward compat ible with the previous generation of SpectrAlert notification appliances Horn strobe products are available in two versions The 2 wire products fit systems where a single NAC controls both horn and strobe The 4 wire products are in ten...

Страница 2: ...for the specific candela selection in Table 1 with the current draw for the specific horn selec tion in Table 3 Table 1 Strobe Current Draw for S SC P4 PC4 Series Candela 8 17 5 Volts 16 33 Volts DC FWR DC FWR Standard Candela Range 15 123 128 66 71 15 75 142 148 77 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High Candela Range 135 NA NA 228 207 150 NA N...

Страница 3: ...n the ones supplied with the product 2 The wall mount box SA WBB or SA WBBW must be mounted with its internal post in the lower left corner as shown in Figure 8 3 Threaded holes are provided in the sides of the box for inch conduit adapters Knockout plugs in the back of the box can be used for inch rear entry Unused holes must be sealed Plugs and O Rings are provided with the box for this purpose ...

Страница 4: ... limited to the replacement of any part of the product which is found to be defective in materials or workmanship under normal use and service during the three year period commencing with the date of manufacture After phoning System Sensor s toll free number 800 SENSOR2 736 7672 for a Return Authorization number send defective units postage prepaid to System Sensor Returns Department RA __________...

Отзывы: