background image

D400-02-01                                                                                               4                                                                                              I56-277-10R

                                                                                                                                                                                                ©2004 System Sensor

System  Sensor  warrants  its  enclosed  smoke  detector  to  be  free  from 
defects in materials and workmanship under normal use and service for a 
period of three years from date of manufacture. System Sensor makes no 
other express warranty for this smoke detector. No agent, representative, 
dealer, or employee of the Company has the authority to increase or alter 
the  obligations  or  limitations  of  this  Warranty.  The  Company’s  obliga-
tion of this Warranty shall be limited to the repair or replacement of any 
part of the smoke detector which is found to be defective in materials or 
workmanship under normal use and service during the three year period 
commencing with the date of manufacture. After phoning System Sensor’s 
toll  free  number  800-SENSOR2  (736-7672)  for  a  Return  Authorization 
number,  send  defective  units  postage  prepaid  to:  System  Sensor,  Repair 

Maintenance

It  is  recommended  that  the  detector  be  removed  from  its 
mounting base to facilitate easier cleaning. The detector is 
cleaned as follows:

NOTE:

  Before  removing  the  detector,  notify  the  proper 

authorities  that  the  smoke  detector  system  is 
undergoing  maintenance  and  will  temporarily  be 
out of service. Disable the zone or system undergo-
ing maintenance to prevent unwanted alarms.

1. Remove  the  detector  cover  by  placing  a  small  bladed 

screwdriver in the side slot of the detector cover, twist-
ing it slightly until the cover can be turned counterclock-
wise for removal.

2. Vacuum the screen carefully without removing it. If fur-

ther cleaning is required continue with Step 3, otherwise 
skip to Step 6.

3. Remove the screen by pulling it straight out (see Figure 

2). Vacuum the inside.

4. Clean the vaned chamber piece by vacuuming or blow-

ing out dust and particles.

5. To  replace  the  screen,  orient  it  so  that  the  arrow  on 

top  aligns  with  the  test  module  socket  of  the  detector. 
Carefully push the screen onto the base making sure it 
fits tightly to the chamber.

6. Replace the cover by gently rotating it clockwise until it 

locks in place.

7. Reinstall the detector.

8. Notify the proper authorities that the system is back on 

line.

Please refer to insert for the Limitations of Fire Alarm Systems

Three-Year Limited Warranty

Department, RA #__________, 3825 Ohio Avenue, St. Charles, IL 60174. 
Please  include  a  note  describing  the  malfunction  and  suspected  cause 
of failure. The Company shall not be obligated to repair or replace units 
which  are  found  to  be  defective  because  of  damage,  unreasonable  use, 
modifications,  or  alterations  occurring  after  the  date  of  manufacture.  In 
no case shall the Company be liable for any consequential or incidental 
damages for breach of this or any other Warranty, expressed or implied 
whatsoever, even if the loss or damage is caused by the Company’s neg-
ligence or fault. Some states do not allow the exclusion or limitation of 
incidental or consequential damages, so the above limitation or exclusion 
may not apply to you. This Warranty gives you specific legal rights, and 
you may also have other rights which vary from state to state.

Содержание 2451, 2451TH

Страница 1: ...er 4 0 inches 101 cm Weight 0 5 lb 277 g Operating Temperature Range 0 C to 49 C 32 F to 120 F Operating Humidity Range 10 to 93 Relative Humidity Maximum Air Velocity 3000 Ft Min 15 M S Locking Alarm Reset by momentary power interruption Fixed Temperature Thermal 135 F 57 C Two LEDs on each detector light to provide a local 360 visible alarm indication They flash every ten seconds indi cating tha...

Страница 2: ... the detector mounting bracket then install the detector To remove the detector from the bracket once it has been made tamper resistant use a pocket screwdriver or similar tool to depress the tamper resistant tab located in the slot on the mounting bracket Then turn the detector counterclockwise until it separates from the base 3 After all detectors have been installed apply power to the control u...

Страница 3: ...arm 4 Remove the test card by sliding it clockwise before removing then insert the ALARM end 5 The LEDs should latch on within 20 seconds indicat ing alarm and annunciating the panel 6 Put the cover back by gently rotating it clockwise until it locks in place C Test Module System Sensor no MOD400R The MOD400R is used with your DMM or voltmeter to check the detector sensitivity as described in the ...

Страница 4: ...r can be turned counterclock wise for removal 2 Vacuum the screen carefully without removing it If fur ther cleaning is required continue with Step 3 otherwise skip to Step 6 3 Remove the screen by pulling it straight out see Figure 2 Vacuum the inside 4 Clean the vaned chamber piece by vacuuming or blow ing out dust and particles 5 To replace the screen orient it so that the arrow on top aligns w...

Отзывы: