TFT/HxxxxPU71x16-xxx: user documentation
DOC/Protouch-71; V1.0
© Syslogic Datentechnik AG, CH-5405 Baden-Dättwil, Switzerland, http://www.syslogic.com
25
/
27
1.1.2.
Immunity
Immunity requirements according to 2004/108/EC harmonized standard EN61000 -6-4
Test
Standard
Limit
Electro-static discharge / ESD
EN61000-4-2:2009
IEC61000-4-2:2008
EN61000-6-2, EN55024
6kV contact - direct
6kV contact – indirect
8kV air
RF electromagnetic field
1kHz, 80% AM
EN61000-4-3:2006
+A1:2008+A2:2010
IEC61000-4-3:2006
+A1:2007+A2:2010
EN61000-6-2, EN55024
80 – 1000MHz: 20V/m
1.4..2.1GHz: 10V/m
2.1..2.5GHz: 5V/m
2.5..2.7GHz: 1V/m
Criterion A
Electrical fast transients / burst
5/50ns
EN61000-4-4:2004
IEC61000-4-4:2004
EN55024
2.0kV
Criterion A
Surge
1.2/50us
EN61000-4-5:2006
IEC61000-4-5:2005
EN61000-6-2, EN55024
DC power :
2kV (line - earth)
1kV (line – line)
Criterion B
Communication ports :
1kV (shield - earth)
Criterion B
Conducted disturbances
1kHz, 80% AM
EN61000-4-6:2009
IEC61000-4-6:2008
EN61000-6-2, EN550224
All connections:
0.15 – 80MHz: 10V/m
Criterion A
Tab. 14 Immunity requirements
5.3.
Environmental Specification
Parameter
Symbol
min
typ
max
Unit
storage temperature range
Tst
-20
75 °C
Operating altitude
2000 MAMSL
Humidity4 (not condensing)
RH
20
90
%RH
Tab. 15 Environmental Specification
4
above +60°C: < 133.8g/m3