If a file is recorded due to a common trigger condition, this is shown in the
Recording List
(chapter
with the entry
Common
in the column
Reason.
If at the same time in the corresponding MR
also the local criteria for triggering were met, there will be 2 recordings of the same time history, but
with different starting time and duration – the file recorded due to the common trigger overlaps the
file due to the local trigger. The files due to common trigger have the same start time and the same
duration in all the MRs in the network.
To get only files due to a common trigger from the
Recording list
, you will have to apply a filter for
the
Reason
(chapter 4.7).
With the button
Start
and
Stop
, you can also start a new recording among all the sensors present
in the network without waiting for the activation of the common trigger.
4.6.3
Common Alarm 1 and 2
Common Alarm means that there is a voting logic for the alarms. Here you define the conditions for
the voting logic. The procedure is exactly the same as for the common trigger. Make sure to
activate the
Common Alarm
in the tab Contacts to get a message if there is a common alarm.
Figure 4.6.3. Subsection dedicated to the common alarms.
MR3000CMR3000C_TR_v2.0_rev1.odt
subject to technical change without notice
73