11
Chapter 3 — Specification
3.1 Equipment Specification
GENERAL
Regulatory Conformity
FCC, CE,
R
o
HS
ELECTRICAL
Input Voltage
12 VDC
Power Consumption
3W
Communication
RS-485
BNC Video Input
Connection camera video port(1Vp-p 75 Ohm unbalanced)
BNC Video Output
To Monitor BNC port(1Vp-p 75 Ohm unbalanced)
MECHANICAL
5
Dimension
13.79x4.75x1.73 (Unit : inch) / 350x120.5x44 (Unit : mm)
Unit Weight
Approx. 44.80 (Unit : oz) / 1.27 (Unit : kg)
Shipping Weight
Approx. 75.14 (Unit : oz) / 2.13 (Unit : kg)
Shipping Size
19.88 x 8.46 x 6.69 (Unit : inch) / 505 x 215 x 170 (Unit : mm)
ENVIRONMENT
Operation Temperature
0
°
C to 35
°
C (32
°
F to 95
°
F)
Operating humidity
10% to 90%RH (non-condensing)
Storage temperature
-20
°
C to 60
°
C ( -4
°
F to 140
°
F)
Specifications are subject to change without notice.
3.2 Signal Strengths by Video Cable Types
Refer to the chart below for the minimum cable requirements and the maximum cable distance
by cable types.
●
Minimum Cable Requirements
- 75 ohms impedance
- All copper center conductor
- All copper braided shield with 95% braid coverage
Cable Types
Maximum Distance
RG59/U 750
ft(228m)
RG6/U 1000
ft(304m)