The performance of TS-INOX water heaters has been determined by the Institute for Building
Energetics, Thermotechnology and Energy Storage (IGTE) at the University of Stuttgart in Germany
according to EN 12976-2:2006.
The following table summarises the annual performance of TS-INOX, according to location.
Q
d
: heat demand in MJ/a, Q
L
: solar energy yield in MJ/a, f-sol: solar fraction
TS-202INOX
Qd
QL
f-sol
Qd
QL
f-sol
Qd
QL
f-sol
MJ/a
MJ/a
%
MJ/a
MJ/a
%
MJ/a
MJ/a
%
litres/day
80
110
140
Stockholm
4441
2509
56.5
6107
3120
51.1
7772
3590
46.2
Würzburg
4257
2549
59.9
5854
3202
54.7
7450
3717
49.9
Davos
4820
3778
78.4
6628
4646
70.1
8435
5280
62.6
Athens
3305
2977
90.1
4545
3849
84.7
5784
4580
79.2
Qd
QL
f-sol
Qd
QL
f-sol
Qd
QL
f-sol
MJ/a
MJ/a
%
MJ/a
MJ/a
%
MJ/a
MJ/a
%
litres/day
170
200
250
Stockholm
9437
3925
41.6
11103
4130
37.2
13878
4302
31.0
Würzburg
9047
4116
45.5
10643
4374
41.1
13304
4563
34.3
Davos
10243
5695
55.6
12050
5940
49.3
15063
6145
40.8
Athens
7023
5197
74.0
8263
5701
69.0
10328
6289
60.9
TS-304INOX
Qd
QL
f-sol
Qd
QL
f-sol
Qd
QL
f-sol
MJ/a
MJ/a
%
MJ/a
MJ/a
%
MJ/a
MJ/a
%
litres/day
140
170
200
Stockholm
7820
4698
60.1
9492
5392
56.8
11163
5960
53.4
Würzburg
7442
4698
63.1
9113
5487
60.2
10627
6054
57.0
Davos
8483
7127
84.0
10280
8104
78.8
12109
8924
73.7
Athens
5834
5424
93.0
7064
6370
90.2
8325
7221
86.7
Qd
QL
f-sol
Qd
QL
f-sol
Qd
QL
f-sol
MJ/a
MJ/a
%
MJ/a
MJ/a
%
MJ/a
MJ/a
%
litres/day
250
300
400
Stockholm
13938
6717
48.2
16745
7158
42.7
22327
7379
33.0
Würzburg
13276
6906
52.0
15925
7474
46.9
21223
7820
36.8
Davos
15137
9870
65.2
18164
10375
57.1
24219
10596
43.6
Athens
10406
8420
80.9
12488
9334
74.7
16651
10596
63.6