Synway Information Engineering Co., Ltd
LED
Lamp Status
Implication
ON synchronous
Flash asynchronous
Green Lamps
OFF
idle port
Table 2-1 On-board Synchronization Indicators
Hot-swap Indicator
Lamp Status
Runtime Status
ON
in the course of hot-swap
Blue Lamp
OFF normal
Table 2-2 Hot-swap Indicator
③
Interfaces on outlet boards are all RJ48C connectors. Users may convert them into BNC
connectors by using the RJ48C-to-BNC adapter supplied with the board. Board models
introduced in this file are all listed below.
No.
Model
Trunk
Associated
Outlet Board
Physical
Interface
RSD042
1 common RJ48C
1 TEJ100P(SSW)
1E1/T1/J1
RSD043 2
L9
RSD042
1 common RJ48C
2 TEJ101P(SSW)
1E1/T1/J1
RSD043 2
L9
RSD042
2 common RJ48C
3 TEJ200P(SSW)
2E1/T1/J1
RSD043 4
L9
RSD042
2 common RJ48C
4 TEJ201P(SSW)
2E1/T1/J1
RSD043 4
L9
RSD042
4 common RJ48C
5 TEJ400P(SSW)
4E1/T1/J1
RSD043 8
L9
RSD042
4 common RJ48C
6 TEJ401P(SSW)
4E1/T1/J1
RSD043 8
L9
RSD081
8 common RJ48C
7 TEJ800P(SSW)
8E1/T1/J1
RSD082
4 special RJ48C
RSD081
8 common RJ48C
8 TEJ801P(SSW)
8E1/T1/J1
RSD082
4 special RJ48C
Table 2-3 Board Model List
2.2 System
Requirements
Host System Requirements
CPU: 800MHz Intel® Pentium®
Ⅲ
or above
Memory: 64M or more
HD: Depends on individual requirements
Special-for-Switch TEJ Digital Trunk Interface Boards Hardware Manual
(Ver 1.0) Page 11