Synway Information Engineering Co., Ltd
UMCT Intelligent Switch Hardware Manual
(Ver. 1.3)
Page 7
If the power supply module works normally, the indicator lights up green; if it goes abnormal, the
indicator lights up orange and an alarm buzzes. To stop the alarm, pull out the abnormal power
supply module.
The method to insert or extract the power supply:
To insert the power supply module, push it home into the slot until it can go no further. To extract
the power supply module, open the power lock catch by pulling it toward the power fan and draw
the power supply module until it is completely out.
SSW080C supports the 5
” hard disk, but it requires SCU08 or above.
The method to install the HD:
a) Disassemble the two vacant panels beside the RCU outlet board, and take out the HD
installation bracket.
b) Use the HD shock pad and screws to fix the hard disk onto the HD installation bracket.
c) Connect the flat cable properly for the HD.
d) Plug back the HD installation bracket and reinstall the two vacant panels. Now the HD
installation finishes.
See Table 1-5 for the board models supported by SSW080A/SSW080B/SSW080C.
Series
Board Model
Available
Ports per
Board
Max.
Inserted
Boards
Note
SHD
SHD-30E-CT/PCI(SSW)
30
8
Up to 64 E1 digital
interfaces configurable
per system, with the
maximum capacity of
1920 ports
Up to 512 fax channels
available per system
SHD-30E-CT/PCI/EC(SSW)
30
SHD-60E-CT/PCI(SSW)
60
SHD-60E-CT/PCI/EC(SSW)
60
SHD-120E-CT/PCI(SSW)
120
SHD-120E-CT/PCI/EC(SSW)
120
SHD-240E-CT/PCI(SSW)
240
SHD-240E-CT/PCI/EC(SSW)
240
SHD-30E-CT/PCI/FAX(SSW)
30
SHD-60E-CT/PCI/FAX(SSW)
60
SHD-120E-CT/PCI/FAX(SSW)
120
SHD-240E-CT/PCI/FAX (SSW)
240
SHT
SHT-16C-CT/PCI/EC(SSW)
16
Up to 128 analog trunk
channels configurable
per system
SHT-16C-CT/PCI/FAX(SSW)
SHN
SHN-8B-CT/PCI+(SSW)
8
Up to 960 VoIP
channels available per
system
SHN-16B-CT/PCI+(SSW)
16
SHN-32B-CT/PCI+(SSW)
32
SHN-60B-CT/PCI+(SSW)
60
SHN-120B-CT/PCI+(SSW)
120
DST
DST-24B/PCI(SSW)
24
Up to 192 channels
available per system
TEJ
TEJ101P(SSW)
30
Up to 64 E1 digital
interfaces configurable
per system, with the
maximum capacity of
1920 ports
TEJ201P(SSW)
60
TEJ401P(SSW)
120
TEJ801P(SSW)
240
FXM
FXM3201P(SSW)
32
Up to 256 voice
channels per system,
inclusive of 96 station
channels at most for
SSW080A/B and 256
station channels at most
for SSW080C.