Страница 1: ...Synway UMCT Series SSW020 Series SSW030 Series SSW080 Series UMCT Intelligent Switch Version 1 3 Synway Information Engineering Co Ltd www synway net...
Страница 2: ...SW020A 2 0 1 1 2 SSW030A 3 1 3 SSW080A SSW080B SSW080C 4 Chapter 2 Installation 8 2 1 Hardware Installation 8 2 2 Turnon Turnoff 10 2 2 1 Turn on Operation 10 2 2 2 Turn off Operation 11 2 3 Hot Repla...
Страница 3: ...y means electronic or mechanical without prior written permission from Synway Information Engineering Co Ltd hereinafter referred to as Synway Synway reserves all rights to modify this document withou...
Страница 4: ...0 7 Add description on the new UMCT intelligent switch model SSW020A Version 1 2 2013 7 Add description on the new UMCT intelligent switch model SSW020A 2 0 Update some board information and relative...
Страница 5: ...Max Inserte d Boards RCU01 RCU02 RCU04 SSW020 2 SSW020 2 0 3 SSW030A 3 SSW080A 8 SSW080B 8 SSW080C 8 SSW080C DC 8 Note A single switch can accommodate only a piece of SCU as well as a piece of RCU but...
Страница 6: ...W 30 2 Up to 16 E1 digital interfaces configurable per system with the maximum capacity of 480 ports Up to 128 fax channels available per system SHD 30E CT PCI EC SSW 30 SHD 60E CT PCI SSW 60 SHD 60E...
Страница 7: ...orts two options for power supply 220V AC and 110V AC which can be selected by the voltage switch Note Make sure the voltage option you choose conform to the actual voltage input before you power on t...
Страница 8: ...FXM3201P SSW 32 2 Up to 64 voice channels available per system Table 1 4 Model List of Functional Boards 1 3 SSW080A SSW080B SSW080C The SSW080A SSW080B and SSW080C UMCT intelligent switches are 6U i...
Страница 9: ...240V 47 63Hz and the maximum current of 4A Figure 1 7 SSW080B Front Panel Figure 1 8 SSW080B Rear Panel Note Apart from the redundant power supply the rear panel of SSW080A is the same as that of SSW0...
Страница 10: ...supports both AC power and 48V DC power where lies the difference from SSW080B What s more AC and DC power modules are allowed to work together to further guarantee the operating stability The front...
Страница 11: ...rd models supported by SSW080A SSW080B SSW080C Series Board Model Available Ports per Board Max Inserted Boards Note SHD SHD 30E CT PCI SSW 30 8 Up to 64 E1 digital interfaces configurable per system...
Страница 12: ...on the chassis and draw it horizontally out Note Pulling out the SCU during system runtime may result in such problems as system shut down or data missing Therefore don t forget to close the system b...
Страница 13: ...prevention of accidental removal See Figure 2 4 above To pull the board out first loosen off the screws on the panel and press both red buttons on the board handle at the same time Wait until the boa...
Страница 14: ...d 2 2 Turnon Turnoff 2 2 1 Turn on Operation First of all check if the power cord is connected properly if the HD and the memory on the SCU is intact if all necessary boards are well installed and if...
Страница 15: ...l out the one to be replaced Insert the new board and start it in the system This operation is now completed Note Directly pulling out boards with relative applications unclosed may result in data los...
Страница 16: ...2U Chassis Step2 Loosen off the screws shown in Figure 2 10 and draw out the damaged fan plate Note The fan plate can not be taken out vertically Please incline it a little bit to right and then pull...
Страница 17: ...age 13 Step2 Loosen off the screws that fix the fan plate and tear down the broken fans Replace them with new fans and tighten up the screw to fix the fan plate See Figure 2 12 below Figure 2 12 Fans...
Страница 18: ...ce Level 4 Certification FCC CE Physical Size Height 44 2 mm 1U Width 442mm 19 Depth 362mm Weight 4 6kg Power Requirements AC 220V 110V Frequency 50Hz 60Hz Maximum power 200W Environment Well ventilat...
Страница 19: ...effectively hold back electromagnetic interference Physical Size Height 266mm 6U Width 442mm 19 Depth 373 5mm Weight 16 18kg Power Requirements AC 100V 240V Frequency 47Hz 63Hz Maximum power 250W Env...
Страница 20: ...uipped with EMI circuit to effectively hold back electromagnetic interference Physical Size Height 266mm 6U Width 442mm 19 Depth 373 5mm Weight 16 18kg Power Requirements DC 42 60V Maximum power 480W...
Страница 21: ...ce board Clean the slot of the board 5 Hot Swap indicator always on Improper board installation leads to abnormality in power supply 6 System fails to find the board a Bad contact of board Clean the s...
Страница 22: ...lp you Headquarters Synway Information Engineering Co Ltd http www synway net 9F Synway D R Center No 3756 Nanhuan Road Binjiang District Hangzhou P R China 310053 Tel 86 571 88860561 Fax 86 571 88850...