background image

                                       

                             

Synway Information Engineering Co., Ltd

 

Appendix B Technical Specifications of FXM-16A/PCIe 

Up to 10 boards concurrently per system; 
up to 16 channels per board 

Dimensions 

280×111mm

2

 (excluding L-bracket) 

Power Requirements 

Weight 

+3.3V DC: 3A 

200g (Excluding modules and external 

power supply) 

+12V DC: 0.5A 

Maximum power consumption: 

12W (PC 

power only) 

Environment 

Operating temperature: 0

—55

 

Impedance 

Storage temperature: -20

—85

 

Input impedance: 

1M

/500V DC;    

10k

/1000Hz AC 

Humidity: 8%—90% non-condensing 

Storage humidity: 8%—90% 

non-condensing 

Insulation resistance for PC isolation from 
telephone line: 

2M

/500V DC 

Input/output Interface 

Telephone line impedance: 

Telephone line jack: Four 8-pin RJ45 

Compliant with the national standard 
impedance for three-component network 

Ringing current & battery feed power 
supply jack: One 4-pin MPC-4 

Audio Encoding & Decoding 

Audio Specifications 

A-Law          64kbps 

CODEC: CCITT A/µ-Law 64kbps 

μ

-Law        

64kbps 

Distortion: 

3% 

Sampling Rate 

Frequency response: 300-3400Hz (±3dB) 

8kHz 

Signal-to-noise ratio: 

38dB 

Safety 

Echo suppression: 

40dB 

Lightning resistance: Level 4 

Maximum System Capacity 

 

Synway FXM series Hardware Manual

Version 1.0

                                                                                 

   

 Page 14 

Содержание FXM-16A/PCIe

Страница 1: ...Synway AST Series FXM 8A PCI FXM 16A PCIe Version 1 0 Synway Information Engineering Co Ltd www sanhuid com...

Страница 2: ...le 3 Chapter 2 Installation 5 2 1 Hardware Structure 5 2 2 Module Identification 6 2 3 Interface Identification 8 2 3 1 RJ11 8 2 3 2 RJ45 8 2 4 Slot Compatibility 9 2 5 System Requirements 10 2 6 Hard...

Страница 3: ...is manual you agree to the following Software License Agreement Synway reserves the right to revise this manual without prior note Please contact Synway for the latest version of this manual before pl...

Страница 4: ...n Engineering Co Ltd Revision History Version Date Comments Version 1 0 2009 02 Initial pubication Note Only major revisions to this manual itself recorded herein Synway FXM series Hardware Manual Ver...

Страница 5: ...t applicable to secondary development Figure 1 1 is a typical application model with FXM xxx represents the existing and future board models in the FXM series Figure 1 1 Typical Application FXM 8A PCI...

Страница 6: ...wling and minimizing the possibility of registering wrong DTMF and busy tones in a conference call designed especially for VoIP application environments z Voice CODEC Support Supports the hardware bas...

Страница 7: ...zing the possibility of registering wrong DTMF and busy tones in a conference call designed especially for VoIP application environments z Voice CODEC Support Supports the hardware based A law law cod...

Страница 8: ...r Analog Line Interface Circuit Subscriber Line Interface Circuit Voltage Detector Ring Detector Ring Control Hook Detector Echo Canceler Trunk Board Subscriber B d Outbound Voice Phone Interface CODE...

Страница 9: ...odule Slot4 Ch7 Ch8 P R Ch1 Ch2 Ch3 Ch4 Ch5 Ch6 Ch7 Ch8 Led Jack 1 2 3 4 5 6 7 8 Figure 2 1 FXM 8A PCI Left and Front Views Note As shown in Figure 2 1 above the numbers for led jacks from left to rig...

Страница 10: ...proof circuit that reaches the telecom standard and three of them at the same time z FXO Trunk Module Th module is equipped with connects its corresponding channel directly to local lines from Centra...

Страница 11: ...up to 5 5km Refer to Figure 2 7 and Figure 2 8 for hardware structure Figure 2 7 Front View Figure 2 8 Rear View z Composite Module A composite module accommodates a trunk channel and a station chann...

Страница 12: ...ent module interface may be FXO FXS or composite module Jacks 1 4 from top to bottom correspond to Modules 1 4 A single board of FXM 8A PCI can be equipped with up to 4 dual channel modules and suppor...

Страница 13: ...PCI Slot Slot Number 0 AGP Pro Slot 1 64 bit 5 0V PCI Slot 2 64 bit 3 3V PCI Slot 3 32 bit 5 0V PCI Slot 4 PCI E Slot The FXM 8A PCI board includes PCI 2 2 bus with burst data transmission rate up to...

Страница 14: ...to 2 channels The two leads in the middle constitute a port and the outer two leads set up another See Table 2 1 above for the pin layout and the corresponding channel number Each RJ11 jack can be co...

Страница 15: ...4 Correspondence between Channels Pins in RJ45 and Interfaces of 4 way Hub Step 3 Connect to the ringing current battery feed power supply Note Skip this step if FXS station module is not used in the...

Страница 16: ...td module to establish an application environment Step 5 Boot your computer and install the driver Regarding driver installation refer to the file SynAST UserManual doc for details Synway FXM series H...

Страница 17: ...1M 500V DC 10k 1000Hz AC Storage humidity 8 90 non condensing Insulation resistance for PC isolation from telephone line 2M 500V DC Input output Interface Ringing current battery feed power supply jac...

Страница 18: ...90 non condensing Storage humidity 8 90 non condensing Insulation resistance for PC isolation from telephone line 2M 500V DC Input output Interface Telephone line impedance Telephone line jack Four 8...

Страница 19: ...about Asterisk please keep touch with Digium Inc for help Headquarters Synway Information Engineering Co Ltd http www synway net 9F Synway D R Center No 3756 Nanhuan Road Binjiang District Hangzhou P...

Отзывы: