Section II
General Product Information
006-0006504 02/27/18
Rev R
10 of 56
UPS-3000 Guide
www.synqor.com
Part Numbering Scheme and Options
This table shows the part numbering scheme for the full line of SynQor UPS products:
Family Output Power Battery Pack
Size
Height
AC Input
Frequency
AC Output
Voltage
AC Output
Neutral Wire
AC Output
Set Point
Frequency
DC Input /
DC2 Output
Dual DC1
Output
Voltage
Additional Options
UPS
3000
S
2U
L
1
G
6
D
28
000
UPS 3000:
3000 VA
2500 W
S:
Standard
2U:
3.40”
L:
W:
47-65 Hz
47-800 Hz
1:
2:
5:
6:
4:
50 Hz
60 Hz
400 Hz
S:
Not Installed
00:
None
000:
None
D:
DC Input
12:
12 V
0CE:
CE Marking
G:
Grounded
M:
DC2 Out
15:
15 V
E00:
Ethernet /
115 Vrms
F:
Floating *
24 VDC with
24:
24 V
SNMP
230 Vrms
R:
AC Output
Droop Share
28:
28 V
ECE:
Ethernet /
Electronic
R:
DC2 Out
40:
40 V
SNMP &
Breaker *
28 VDC with
50:
50 V
CE Marking
Droop Share
Not all combinations make valid part numbers, please contact SynQor for availability. See the Product Summary web page for more options.
* Note:
Order “F: Floating” option when configuring the AC output for multi-unit combinations of up to 3 units.
Order “R: AC Output Electronic Breaker” option for fault-tolerant, glitch-free parallel systems of up to 32 units with N+M redundancy;
The AC output neutral wire will not be connected to the chassis
Example:
UPS-3000-S-2U-L1G6D28-000
The UPS-3000 Series of products provide up to 3000 VA and 2500 W of total output power
(AC plus DC).
• A 2U high, 65 lbs. rackmount unit that uses two standard battery packs which provide >10 minutes of battery
run-time at full power
Each format has various options that can be specified according to the part numbering scheme
shown in the table:
• The allowable frequency of the AC INPUT can either be in the 47-65 Hz range (for 50 Hz and/or 60 Hz systems)
or in the 360-800 Hz range (for 400 Hz and Variable Frequency systems)
• The output voltage of the UPS-3000 Series can be 115 Vrms or 230 Vrms.
• The AC output can be configured with its neutral wire internally grounded to the chassis of the UPS or left
floating for shipboard applications.
• The initial set-point frequency of the AC OUTPUT voltage can be 50 Hz, 60 Hz or 400 Hz. Regardless of the initial
set-point frequency, the actual frequency can be set through the communications/control port.
• There is an optional DC INPUT that is specified to comply with MIL-STD-704F and MIL-STD-1275D for 28 V
systems.
• Two optional DC OUTPUT capabilities are available: DC1 with up to 2x500 W capability, and DC2 with up to
2500 W capability.
• RS232 serial port and logic-level I/O communication are included in the standard model. An Ethernet port
providing web and SNMP interfaces is an available option.
• The Electronic Breaker option adds fault tolerant, glitch free multi-unit operation for N+1 or N+M redundancy.
This option also allows up to 32 units to be combined to form single-phase, split-phase, or 3-phase systems
The UPS-3000S-2U data sheet showing these specifications and other information can be found
at the web site
www.SynQor.com/UPS
.