Chapter 2: Hardware Setup
LED Indicator Table
Location
LED Indicator
Color
Status
Description
Front Panel
Power
Blue
Static
Powered on
Blinking
Booting up / Shutting down on one of the controller
Both controllers are booting up / shutting down
Off
Powered off
HA STATUS
Green
Static
Both controllers are powered on and HA (High Availability)
status is normal
Orange
Blinking
Both controller modules are installed and powered on
,
but
HA (High Availability) status is abnormal
Both controller modules are installed, one of the controller is
powered on while the other is booting up
Only one controller module is installed and powered on
Off
Both controllers are booting up
Only one controller module is installed and booting up
ALERT
1 2
Orange
Blinking
Fan failure / Over temperature on one controller while the
other is normal
Fan failure / Over temperature on both conrollers
Off
System normal
Both controllers are booting up
Drive Status Indicator
(on tray)
Green
Static
Drive ready and idle
Blinking
Accessing drive
Red
Static
Drive error / Port disabled
3
Off
No internal drive
1
If one controller is powered on while the other is booting up, the ALERT indicator will display the controller's status that is powered on.
2
If the system contains only one controller, the ALERT indicator will only display that controller's status.
3
Please try to restart your Synology
Unified Controller
or re-insert the drive(s), and then run the HDD/SSD manufacturer's diagnostic tool to check the health
status of the drive(s). If you can log into DSM UC, please run the built-in S.M.A.R.T. test to scan the drive(s). If the problem remains unresolved, please
contact Synology Technical Support for help.