background image

Thank you for purchasing Synology RX1217sas expansion unit! Before setting up your new expansion unit, 
please check the package contents to verify that you have received the items below. Also, make sure to read the 
safety instructions carefully to avoid harming yourself or damaging your Synology product.

Note: 

All images below are for illustrative purposes only, and may differ from the actual product.

Package Contents

Expansion unit x 1

AC power cord x 2

Quick Installation Guide x 1

Screws for 3.5” drives x 52

Screws for 2.5” drives x 52

Expansion cable x 1

Before You Start

1

 

3

 

Chapter

Содержание RX1217sas

Страница 1: ...Expansion Unit RX1217sas Hardware Installation Guide ...

Страница 2: ...Chapter 2 Hardware Setup Tools and Parts for Drive Installation 6 Install Drives 6 Connect with Synology NAS Server 8 Chapter 3 Maintenance Replace Malfunctioning PSU 10 Replace Malfunctioning SAS Fan Module 11 Appendix A Specifications Appendix B LED Indicator Table Synology_HIG_RX1217sas_201601018 2 ...

Страница 3: ...ake sure to read the safety instructions carefully to avoid harming yourself or damaging your Synology product Note All images below are for illustrative purposes only and may differ from the actual product Package Contents Expansion unit x 1 AC power cord x 2 Quick Installation Guide x 1 Screws for 3 5 drives x 52 Screws for 2 5 drives x 52 Expansion cable x 1 Before You Start 1 3 Chapter ...

Страница 4: ...ools the PSU 10 STATUS Indicator Displays the status of the system For more information please see Appendix B LED Indicator Table 11 ALERT Indicator Displays warnings regarding fan or temperature For more information please see Appendix B LED Indicator Table 12 Expansion Unit ID Indicator Indicates the ID number of the expansion unit 13 SAS IN Port and Indicator Connects to the SAS OUT port of a S...

Страница 5: ...er cord Wipe with damp paper towels Do not use chemical or aerosol cleaners To prevent the unit from falling over do not place on carts or any unstable surfaces The power cord must plug in to the correct supply voltage Make sure that the supplied AC voltage is correct and stable To remove all electrical current from the device ensure that all power cords are disconnected from the power source Risk...

Страница 6: ...ay a Find the small button located on the left side of the drive tray handle Press the button down and the drive tray handle will pop out b Pull the drive tray handle out as illustrated above 2 Load drives in the drive trays For 3 5 drives Place the drive in the drive tray Turn the tray upside down and tighten screws into the four spots indicated below to secure the drive For 2 5 drives Place the ...

Страница 7: ...roperly 4 Push the handle inward to secure the drive tray 5 Push the switch on the drive tray handle to the left to lock the drive tray 6 Repeat the steps above to assemble the other drives you have prepared 7 Drives are numbered as shown below Note If you want to create a RAID volume we recommend that all installed drives are of the same size to make the best use of drive capacity ...

Страница 8: ...ard when plugging into RX1217sas otherwise the Synology NAS server and expansion unit will not be correctly connected 2 Connect one end of the power cord s to the power port of RX1217sas and the other to the power outlet s RX1217sas will automatically power on once the power cords are correctly connected Note Your RX1217sas comes equipped with a redundant power supply system allowing two power cor...

Страница 9: ...l connect them with one or more RX1217sas if needed To do so repeat step 1 and 2 above to connect the expansion cables and power cords of the other expansion units Your expansion units will automatically power on if they are correctly connected and the Expansion Unit ID will be displayed accordingly after a few seconds if DSM is installed in the Synology NAS server 2 The actual number of expansion...

Страница 10: ...Beep Off button you can silence the long beeping sound when you hear it 2 RX1217sas supports component hot swapping but we recommend unplugging all power cables of the expansion unit before replacing any component 2 Push the lever of the PSU at the back panel in the indicated direction 3 Pull out the PSU from the expansion unit 4 Prepare a new PSU and push it back to the slot until you hear a clic...

Страница 11: ...lace the malfunctioning SAS fan module 1 Unplug the expansion cables from the SAS fan module on which the malfunctioning module is to be replaced 2 Push the lever of the SAS fan module at the back panel in the indicated direction The modules are numbered as shown below 3 Pull out the SAS fan module from the expansion unit 4 Prepare a new SAS fan module and push it back to the slot until you hear a...

Страница 12: ... the malfunctioning fan by pulling it up from the module The fans are numbered as shown below 2 Prepare a new fan align the arrow to point at the back panel as illustrated below and insert it back into the fan slot 3 Push the module back to the expansion unit until you hear a click ...

Страница 13: ...its Weight kg 18 System Fan 4 x 60 x 60 x 51mm Agency Certification FCC Class A CE Class A BSMI Class A Environment Requirements Line voltage 100V to 240V AC Frequency 50 60Hz Operating Temperature 40 to 95 F 5 to 35 C Storage Temperature 5 to 140 F 20 to 60 C Relative Humidity 5 to 95 RH Note Model specifications are subject to change without notice Please refer to www synology com for the latest...

Страница 14: ...ower supply unit normal Off Power supply unit off SAS IN OUT Green Static Synology NAS server expansion unit connected Off Synology NAS server expansion unit disconnected Note Model specifications are subject to change without notice Please refer to www synology com for the latest information LED Indicator Table B 14 Appendix 1 Please try to restart your Synology NAS server or re insert the drive ...

Страница 15: ...ces hosted by Synology Product to any third party for commercial purpose Section 6 Open Source The Software may contain components licensed to Synology under the GNU General Public License GPL Components currently available at http www gnu org licenses gpl html The terms of the GPL will control solely with respect to the GPL Components to the extent that this EULA conflicts with the requirements o...

Страница 16: ...and finally by arbitration conducted by three neutral arbitrators in accordance with the procedures of the R O C Arbitration Law and related enforcement rules In such cases the arbitration will be limited solely to the dispute between you and Synology The arbitration or any portion of it will not be consolidated with any other arbitration and will not be conducted on a class wide or class action b...

Страница 17: ...roduct during the Warranty Period Synology warrants the Software as set forth in the accompanying end user license agreement provided with the Product if any Synology provides no warranty to Refurbished Product sold as as is or with no warranty on Online Store 2 2 Exclusive Remedy If Customer gives notice of noncompliance with any of the warranties set forth in Section 2 1 within the applicable Wa...

Страница 18: ...RRANTY WHETHER BASED ON CONTRACT TORT INCLUDING NEGLIGENCE STRICT LIABILITY OR OTHER THEORY EVEN IF SYNOLOGY HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES 3 3 Limitation of Liability SYNOLOGY S AND ITS SUPPLIERS LIABILITY ARISING OUT OF OR RELATING TO THE USE OR INABILITY TO USE THE PRODUCT ANY ACCOMPANYING DOCUMENTATION OR SOFTWARE AND ANY OTHER GOODS OR SERVICES PROVIDED UNDER THIS WARRANT...

Страница 19: ...nforcement rules The arbitration shall take place in Taipei Taiwan R O C and the arbitration proceedings shall be conducted in English or if both parties so agree in Mandarin Chinese The arbitration award shall be final and binding on the parties and may be enforced in any court having jurisdiction Nothing in this Section shall be deemed to prohibit or restrict Synology from seeking injunctive rel...

Страница 20: ...ies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation ...

Отзывы: