background image

Using the templates provided, fix the mechanism

to the door as well as the armset and parallel arm 

bracket.

Using the templates provided, mark and drill pilot 

holes into the door and frame.

Connect the main arm and link arm as illustrated

1

2

3

4

Rotate the bottom pinion to approximately 45° 

with a wrench as illustrated and then assemble 

the main arm.

Parallel Fixing

www.synergyhardware.co.uk

Fixing Instructions for

S900 Series 

Door Closer 

Power Adjustable EN 2-6

APPROVED

PRODUCT

CF5294

CPR

AD5330

1121

17

BS EN1154:1997+ A1:2002

4 8 62 1 1 3

www.synergyhardware.co.uk

160

48

10

180°

Closing

Latching

15°

93

59

45

100

SLOW

FAST

Closing 

speed

Latching 

speed

Back

Check

45

°

180°

Closing

Latching

15°

160

48

10

45

59

93

100

SLOW

FAST

Closing 

speed

Latching 

speed

Back

Check

45

°

Ref 45°

Main arm

Link arm

Parallel arm bracket

Link arm

Main arm

Force

Max. door

width

Max. door

weight

Max. 

opening

angle

Number 

of

turns

Direction

FACTORY PRE-SET

0~+2

+2~+6

+6~+9

+9~+12

Clockwise

Clockwise

180°

180°

180°

180°

850mm

950mm

1100mm

1250mm

40kg

60kg

80kg

100kg

2

3

4

5

Fixing in Fig.66

Force

Max. door

width

Max. door

weight

Max. 

opening

angle

Number 

of

turns

Direction

FACTORY PRE-SET

0~+2

+2~+6

+6~+9

+9~+12

Clockwise

Clockwise

180°

180°

180°

180°

850mm

950mm

1100mm

1250mm

40kg

60kg

80kg

100kg

2

3

4

5

Fixing in Fig.66

Parallel arm bracket

Отзывы: