-
51
12. Press once on Enter, for N (no). Use line up/down to scroll when selecting the Y (yes) option.
13. Calibrate the RTC of the terminal to 3.90625 millis 0.00003 by turning the screw on the
variable capacitor at C18.
14. Disconnect Jumper 2 pin at JP13.
15. Replace the JP13 jumper to 1-2 position.
16. Disconnect the connector from TP2 of the terminal’s CPU board.
17. Return the JP12 jumper to re-enable the Watchdog utility.
18. Unplug the terminal.
19. Replace the front panel.
20. Unplug the Time Counter.
Содержание SY-760
Страница 1: ......
Страница 39: ...37 DIRECT RS 232 MULTI DROP RS 485 CONNECTION...
Страница 57: ...55 COMPONENT SIDE PCB NO 770888 01 D...
Страница 58: ...56 PRINTED SIDE PCB NO 770888 01 D...
Страница 59: ...57 DISPLAY CARD...
Страница 68: ...66 P6 19 ON ON SWITCH P6 20 Vs 9v...