Locate an elevated surface and lay the straight edge on surface facing away from
optical head. Check straight edge for level, shim if necessary.
Move
BCA 4
ISO
Color
to end of straight edge, turn on the laser and adjust
height of optical head so that the mounted laser will shoot down the straight edge.
Adjust the rear floor slope wheel until the level in the optical head is centered. Readjustment of
height of optical block may be necessary.
Adjust the rear height adjustment set screw of the laser assembly (Lock Tight has been installed
on screw at factory, minor pressure should break seal) till laser is viewed at both ends of straight
edge equally.
Laser is now calibrated, installing lock tight or other adhesive to adjustment screw is
recommended.
5.2 MAINTENANCE
The
BCA 4 ISOCOLOR
will provide years of trouble free operation with minimum maintenance, however,
care should be taken in the day-to-day usage of this service instrument. Following are areas that should be
periodically checked and serviced;
Check wheel axles nuts for tightness, minor lubrication is
recommended.
Check the optical head mounting bolts for tightness and tighten as
required.
Check all other mounting screws, bolts and nuts for tightness.
Clean the mast area where the brake rides with a mild detergent to
assure of secure holding.
Clean the front lens, sighting unit and viewing window with a mild
detergent being careful to use a non-abrasive soft cloth.
Visually inspect alignment screen for burn holes that could have been
caused by exposure to direct sunlight. Caution should always be
exercised in storing of BCA 4, a placement of a dust cover on unit is
recommended during storage.
6. FREQUENTLY ASKED QUESTIONS
Question: Level in optical head is not centered during alignment procedure?
Answer:
Level vial is used ONLY when checking the calibration of the
FLOOR SLOPE LASER
.
Question: The high intensity (hot spot) area of the headlamp is of a different color that
the other lamp?
Answer:
All lamps are legislated to be created equal, but this has proven not to be the case. Lamp intensities
will vary from lamp to lamp. The intensity of the lamp will determine the color of the high intensity
zone.
Question: Do I have to check for floor slope every time I perform a headlamp
alignment?
Answer:
Floor slope need only be performed one time in each bay that the
BCA 4
ISO
Color
is to be used.
When determining the floor slope, record the reading of the rear eccentric wheel on the sticker