2-3
Main 2/3 Schematic Diagram
L2200XSCM2
CAUTION !
Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit.
If Main Fuse (F601) is blown , check to see that all components in the power supply
circuit are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.
For continued protection against risk of fire,
replace only with same type 4 A, 125V fuse.
CAUTION ! :
ATTENTION :
Utiliser un fusible de rechange de m
ê
me type de 4A, 125V.
4A/125V
NOTE:
The voltage for parts in hot circuit is measured using
hot GND as a common terminal.
MAIN 2/3
Ref No.
Position
IC31
I-3
IC601
I-1
Q31
H-4
Q601
J-2
Q602
J-1
Q662
I-1
Q671
H-2
Q675
H-1
Q676
H-1
Q681
G-2
Q682
G-1
Q683
G-1
CN691
K-2
VR661
H-1
TRANSISTORS
ICS
CONNECTOR
VARIABLE RESISTOR
*
1 NOTE:
These components (C643, C642, JS642)
can be used in any models.
However, you cannot mix components under
Group A with the ones under Group B.
You can choose either Group. The difference
between Group A and Group B is shown below.
C643
C642
4700P/250V
0.01/250V
0.01/250V
Not Used
Not Used
WIRE
JS642
Group A
Group B
Содержание ST413E
Страница 1: ...13 COLOR TELEVISION ST413E 19 COLOR TELEVISION ST419E SERVICE MANUAL...
Страница 43: ...11 5 L2200PEX Packing ST413E X3 X2 S5 S2 S2 S4 S3 X1 X4 PACKING TAPE PACKING TAPE TAPE S6 X5 S1 X6 FRONT...
Страница 55: ...2003 12 05 ST413E ST419E L2200 2300UA...
Страница 67: ...ST413E 6413TE DWT1304 ST419E 6419TE L2200XA L2201XB L2204XE L2300XA L2301XB 2005 03 10...