system may not protect the user from 
scalding when there is a failure of 
other temperature controlling devices 
elsewhere in the plumbing system.

5.  Check packing nut (SC-7) for positive 

frictional resistance to handle turn 
throughout adjustment cycle and at 
shut-off position, tighten if neccessary.  
Check valve cap (SC-2), packing nut 
and all valve, pipe and fitting connec-
tions for leaks. Reattach dome cover 
back onto packing nut.

6.  Be sure that Step 2 has been com-

pleted properly and finish wall is 
in place before proceeding. Slide 
escutcheon assembly (VT-105) over 
dome cover (SC-13/18) already on 
valve body. Carefully align thermometer 
probe with hole in valve body and 
gently push escutcheon against wall. 
Secure escutcheon to valve body with 
two escutcheon screws (WO-20A). 
Mount control handle (VT-112) on valve 
stem. Check handle alignment. Tighten 
handle screw (SC-15A) to mesh slot 
in valve stem. Snap On/Off indicator 
(VT-104) into slot in escutcheon con-
cealing escutcheon screws.

7.  Install shower arm, flange and shower 

head. See figures 2 and 3. Install tub 
spout (1-2100VT only). Use putty 
or sealant on back edge of spout to 
make proper seal with finish wall.

8.   ALLOW VALVE TO RUN IN WARM 

POSITION FOR A FEW MINUTES TO 
TOTALLY FLUSH SYSTEM. IF SYSTEM IS 
QUITE DIRTY, REMOVE VALVE SPINDLE 
OR STOP SPINDLES (IF SO EQUIPPED) 
TO INSURE PROPER FLUSHING. See 
service instructions.

9.  Do not install positive shut-off devices 

on the outlet of this valve or devices 
that do not allow the valve to flow at 
least 1 GPM at 50 psi inlet pressure. 
EXCEPTION: If a self-closing or slow-
closing valve is installed on the outlet, 
the supplies of the valve must be 
equipped with checks to eliminate hot 
to cold by-pass in the event the valve’s 
handle is not turned to off after use. 
Contact your factory representative or 
Symmons directly for information on 
available checks. 

Installation of Tub/Shower System 
Model 1-2100VT(X) (Figure 3)

1.  Follow instructions from previous 

page. Refer to Figure 3.

5" 

(127 mm)

min. without stops

7" (178 mm)

min. with stops

8"

(204 mm)

finished 
wall

shower
discharge

10"

(254 mm)

min.

22"

(559 mm)

Note:

  

Dimensions subject to

           change without notice.

4-3/4"

(119 mm)

see note

hot and 
cold inlets

approx.

36"

(914 mm)

4"

(101 mm)

approx.

42"

(1067 mm)

floor    line

3-1/2"

(89 mm)

NOTE: 2-1/2" (64mm) min.
3" (76mm) max.  On 2"x4"
construction, use 2-1/2"
(64mm) min. rough-in.
Valve inlets and outlets are
1/2" (13mm) IPS connections.

Ø 2-1/4"

(57 mm)

FIGURE 3

Model 1-2100VT(X) Tub/Shower System

FIGURE 4

Fiberglass Wall Installation