INDEX

TECHNICAL DATA

Power supply

Battery box for 6X1.5V AA batteries or 9V transformer

Recommended water 

pressure

0.5-8.0 bar (7-116 PSI) 

For water pressure of more than 8 bars,

use a pressure reducing valve for reduction.

Preset sensor range

180 mm / 7.09” (customizable with optional remote control)

Minimum sensor range

80 mm / 3.15”

Maximum sensor range

300 mm / 11.81”

Security time

90 seconds (can be reduced with optional remote control)

Hot water temperature

Max 70°C

TECHNICAL DATA

PACK CONTENTS

PRE-INSTALLATION INFO

4-7 INSTALLATION

8-9 

SETTINGS ADJUSTMENT

10 

BATTERY REPLACEMENT

11 MAINTENANCE

Filters cleaning instructions
Care and cleaning of chrome and special finishes
Solenoid valve servicing

11 

SPARE PARTS LIST

12 

LIMITED WARRANTY

13 TROUBLESHOOTING

The information in this document reflects products at the date of printing. The manufacturer reserves the right,  subject to all applicable laws, at any time, at its sole discretion, and 

without notice, to discontinue or change the features, designs, materials and other specifications of its products, and to either permanently or temporarily withdraw any of the for-

going from the market. All information in this document is provided “as is” without warranty of any kind, either expressed or implied, including but not limited to any implied war-

ranties of merchantability, fitness for a particular purpose, or non-infringement. The manufacturer assumes no responsibility for errors or omissions in the information presented 

in this document. In no event shall the manufacturer be liable for any special, incidental, indirect or consequential damages of any kind, or any damages whatsoever arising out of 

or in connection with the use or performance of this information. The tradenames, trademarks, logos and service marks presented in this document, including their design, are the 

property of the manufactureror other third parties and you are not permitted to use them without the prior written consent of the manufacturer or such third party as may own them.

Battery version, Ref: S6960B 

Transformer version, Ref: S6960E

Содержание Origins ActivSense S6960B

Страница 1: ...1 S6960B E SENSOR FAUCET ELECTRONIC LAVATORY FAUCET INSTALLATION AND MAINTENANCE GUIDE INSTALLATION AND MAINTENANCE GUIDE...

Страница 2: ...iscretion and without notice to discontinue or change the features designs materials and other specifications of its products and to either permanently or temporarily withdraw any of the for going fro...

Страница 3: ...missing parts WARNINGS Do not install facing a mirror or any other electronic system operated by an infrared sensor To prevent reflection problems it is recommended to keep a minimum distance of 1 50...

Страница 4: ...ING HARDWARE Shut off water supply and remove the hexagonal nut the disk and the gasket Do not remove the o ring from the base of the faucet O ring Gasket Disk Hexagonal nut STEP 2 INSTALLING THE FAUC...

Страница 5: ...ctronic unit to the battery box 2 FOR S6960E a Connect the waterproof connector coming from the electronic unit to the transformer FROM THE ELECTRONIC UNIT TO THE TRANSFORMER b Plug the transformer in...

Страница 6: ...The product will remain shut for 1 minute when this button is pressed once To cancel this function and to return to normal operation press the On Off button again or wait 1 minute RESET BUTTON This f...

Страница 7: ...D CLEANING OF CHROME AND SPECIAL FINISHES DO NOT use steel wool or cleansing agents containing alcohol acid abrasives or the like Use of any prohibited cleaning or maintenance products or substances c...

Страница 8: ...8 bars and yet the pressure in the faucet s body is higher This situation could be caused by a sudden increase in the water supply pressure that the back check prevents from dropping even after water...

Страница 9: ...14 Symmons Industries Inc 31 Brooks Drive Braintree MA 02184 3804 1 800 796 6667 07 2020 01500500 A...

Отзывы: