92
TimeCreator 1000 User’s Guide
097-93100-01 Revision C – February, 2010
Chapter 5 Provisioning
Provisioning the DTI Links
Provisioning the DTI Links
The TimeCreator 1000 rear panel has ten permanent DTI client links that provide
DTI timing signals to client elements in an M-CMTS architecture. With the 8-port
IOC module option, however, only Ports 1 through 6 are active. There are also two
DTI client/server ports that can be provisioned as either DTI reference links (for
subtending servers), or as additional DTI links to client elements. DTI ports 11 and
12 must be provisioned to the appropriate type, either client or server, before being
enabled or disabled.
The LED status indicators on the DTI links are described in
Enabling and Disabling the DTI Server Links
To enable all DTI link ports, perform the following steps:
1. Login at the Admin or Power-User level (see
2. Type
set tod-source dti
and press
Enter
.
3. Type
set interface state all enable
and press
Enter
.
Enabling and Disabling the DTI Client/Server Links
To set up ports 11 and 12 as client DTI links, perform the following steps:
1. Login at the Admin or Power-User level (see
2. Type
set interface type portA client
and press
Enter
.
3. Type
set interface type portB client
and press
Enter
.
4. Type
set interface state port 11 enable
and press
Enter
.
5. Type
set interface state port 12 enable
and press
Enter
.