097-93100-01 Revision C – February, 2010
TimeCreator 1000 User’s Guide 105
Chapter 5 Provisioning
Provisioning Cable Advance
Provisioning Cable Advance
The Cable Advance command allows you to compensate for the response time
between client and server DTI links due to cable length. You can specify any or all
ports and provision for auto correction or manual correction.
Example
To provision cable advance auto mode on DTI link port 1, perform the following
steps:
1. Login at the Admin or Power-User level (see
2. Type
show cable-adv
and press
Enter
to view the current setting.
3. Type
set cable-adv port 1 auto
and press
Enter
.
Provisioning Alarms
This section describes the commands used to provision and manage alarms in the
TimeCreator 1000. The user can provision the alarms to be enabled or disabled and
set thresholds to turn the alarms on and off. For a list of all alarms, see
Software commands allow you to perform the following:
Provision the set and clear alarm thresholds
Provision the alarm-state (enable or disable)
Retrieve current alarm settings
Retrieve current alarms
Display system status
Alarms are also indicated by LEDs on the IOC and IMC modules.
Note:
Symmetricom recommends that you use the automatic cable
advance feature. Refer to the command
The valid range for the manual cable advance value is
from 00:00:00 to 0E:A0:EA.