S100 User Guide – Rev. D – June 2005
91
2
5
3
Leap Indicator (LI)
This is a two-bit code warning of an impending leap second that will be inserted or deleted in
the last minute of the current day, with bit 0 and bit 1, respectively, coded as follows:
Figure 5-42:
Two-bit Leap Second Indicator Code
You are alerted to an alarm condition when the S100 is first powered on—in other words,
before time is initially acquired from the timing signal. An alarm condition will also signal when
the timing parameters are changed. This alarm condition will persist until the S100 acquires
time. It should not signal again until the unit is powered off and on.
Version Number (VN)
This is a three-bit integer indicating the NTP version number. The S100 will return the version
number from the incoming NTP message.
Table Intro-1:
NTP Message Data
LI
VN
MODE
Stratum
Poll
Precision
Synchronizing Distance (Root Distance) (32 bits)
Synchronizing Dispersion (Root Dispersion) (32 bits)
Reference Identifier (32 bits)
Reference Time Stamp (64 bits)
Originate Time Stamp (64 bits)
Receive Time Stamp (64 bits)
Transmit Time Stamp (64 bits)
Authenticator (Optional) (96 bits)
0
8
16
24
31
Содержание SyncServer S100
Страница 2: ...2 S100 User Guide Rev D June 2005 1 ...
Страница 20: ...12 S100 User Guide Rev D June 2005 1 SyncServer S100 ...
Страница 60: ...52 S100 User Guide Rev D June 2005 SyncServer S100 ...
Страница 94: ...86 S100 User Guide Rev D June 2005 SyncServer S100 ...
Страница 108: ...100 S100 User Guide Rev D June 2005 SyncServer S100 Figure 5 43 Large Net NTP Configuration ...
Страница 109: ...S100 User Guide Rev D June 2005 101 2 5 3 Figure 5 44 Large Net NTP Configuration 2 ...
Страница 116: ...108 S100 User Guide Rev D June 2005 SyncServer S100 ...
Страница 126: ...118 S100 User Guide Rev D June 2005 SyncServer S100 ...
Страница 150: ...142 S100 User Guide Rev D June 2005 1 SyncServer S100 ...
Страница 166: ...158 S100 User Guide Rev D June 2005 1 SyncServer S100 ...